8.29.5

Scan Lockout Mode

Following the transmission or reception of a data call, if scan is enabled, scanning will stop temporarily
(two independent pre-programmed times; after a receive data call and after a transmit data call). During
this time the scan indicator will flash to indicate that scan is enabled but temporarily suspended. This
mode is normally exited when the pre-programmed time expires; however, the following actions will
terminate the scan lockout mode before the timeout is completed:

•

The CLEAR button is pressed. The PTT is pressed.

•

The group or system is changed.

•

Phone call mode is entered.

•

Individual call mode is entered.

•

A new emergency assignment has been received.

•

An emergency is declared or cleared.

•

An individual or phone call is received.

•

An Agency, Fleet or System All Call is received.

•

or

is pressed to toggle Scan ON or OFF.

8.29.6

Data Lockout Mode

During the voice call scan hang time (pre-programmed) the radio will not receive data calls.