In addition, resetting the controller causes the system to loose the link
temporarily. Reads and writes occurring when the administrator resets

this controller back to “Primary (Active)” state result in errors because the
drives appear to have been removed. TMS does not recommend

configuring an active secondary controller as primary unless no
transmissions are taking place.

Via Web Interface

To change the failover state via the web interface:

• Click on the “Fibre Channel Controller” graphic.

• Click on the “Controller Setup” tab.

• Select from the “Select failover mode” settings.

• Click the “Save” button.

Figure 7-4: Failover Setup via Web Interface