Electrical Data:
iQP48050A050V-000 through -0x9: 5V, 50A, 250W Output
Characteristic
Min
Typ
Max
Unit
Notes & Conditions
Output Voltage Initial Setpoint
4.88
5
5.12
Vdc
Vin=Vin,nom; Io=Io,max; Tc = 25˚C
Output Voltage Tolerance
4.85
5
5.15
Vdc
Over all rated input voltage, load, and
temperature conditions to end of life
Efficiency
---
91.5
---
%
Vin=Vin,nom; Io=Io,max; Tc = 25˚C
Line Regulation
---
1
10*
mV
Vin=Vin,min to Vin,max, Io and Tc fixed
Load Regulation
---
1
10*
mV
Io=Io,min to Io,max, Vin and Tc fixed
Temperature Regulation
---
5
50
mV
Tc=Tc,min to Tc,max, Vin and Io fixed
Output Current
5
---
50
A
At loads less than Io,min the module will
continue to regulate the output voltage, but
the output ripple may increase slightly
Output Current Limiting Threshold
---
55
---
A
Vo = 0.9*Vo,nom, Tc<Tc,max
Short Circuit Current
---
2
---
A
Vo = 0.25V, Tc = 25
--- 50
100*
mVpp
Output Ripple and Noise Voltage
--- 13.5 --- mVrms
Vin=48V, Io
≥ Io,min, Tc=25˚C. Measured
across one 0.1uF, one 1.0 uF, and one
47uF ceramic capacitors, and one 1000uF
electrolytic capacitor located 2 inches away
– see input/output ripple measurement
figure; BW = 20MHz
Output Voltage Adjustment Range
80
---
110
%Vo,nom
Vin
≥ 38V for trim-up operation
Output Voltage Sense Range
---
---
10
%Vo,nom
Dynamic Response:
Recovery Time to 10% of Peak Deviation
Transient Voltage
---
---
400
150
---
---
µS
mV
di/dt = 1A/uS, Vin=Vin,nom; load step from
50% to 75% of Io,max, Tc=25˚C with at
least one 1.0 uF, one 47uF ceramic
capacitors, and one 1000uF electrolytic
capacitor across the output terminals
Output Voltage Overshoot during startup
0
0
---
mV
Vin=Vin,nom; Io=Io,max,Tc=25˚C
Switching Frequency
---
145
---
kHz
Fixed
Output Over Voltage Protection
5.8*
6.1
6.5*
V
External Load Capacitance
1000
---
25,000
†
uF
Cext,min required for the 100% load dump.
Minimum ESR > 2 m
Ω
Isolation Capacitance
---
1000
---
pF
Isolation Resistance
15
---
---
MΩ
Vref
1.225
V
Required for trim calculation
* Engineering Estimate
†
Contact TDK Innoveta for applications that require additional capacitance or very low ESR