PROBLEM

PROBABLE CAUSE

REMEDY

PAGE

REF.

9. The guide bearing is

missing.

a. The guide bearing is stuck

in the drive shaft.

a. Remove the guide bearing

from the hole in the drive

shaft.

-- --

10. There is excessive

leakage from the door

spout.

a. There is improper or

inadequate lubrication on

the draw valve o-rings.

a. Use an approved food

grade lubricant (example:

Taylor Lube) and follow

the lubrication procedures.

11

b. The draw valve o-ring is

bad or missing.

b. Replace o-rings every

three months.

25

11. The door will not go into

position easily.

a. The beater assembly is

incorrectly positioned.

a. The open end of the

beater assembly should

be in the 11 o’clock

position.

13

Advertising
This manual is related to the following products:

341, 340