Toshiba H1 SERIES TLCS-900 User Manual
Page 206
TMP92CM22
2007-02-16
92CM22-204
AD Conversion Result Register 4 Low
7 6 5 4 3 2 1 0
Bit symbol
ADR41
ADR40
ADR4RF
ADREG4L
(12A8H)
Read/Write R
R
After
reset
Undefined 0
Function
Stores lower 2 bits of AD
conversion result.
AD conversion
data storage
flag
1: Conversion
result
stored
AD Conversion Result Register 4 High
7 6 5 4 3 2 1 0
Bit symbol
ADR49
ADR48
ADR47 ADR46 ADR45 ADR44 ADR43 ADR42
ADREG4H
(12A9H)
Read/Write R
After
reset
Undefined
Function
Stores upper 8 bits of AD conversion result.
AD Conversion Result Register 5 Low
7 6 5 4 3 2 1 0
Bit symbol
ADR51
ADR50
ADR5RF
ADREG5L
(12AAH)
Read/Write R
R
After
reset
Undefined 0
Function
Stores lower 2 bits of AD
conversion result.
AD conversion
data storage
flag
1: Conversion
result
stored
AD Conversion Result Register 5 High
7 6 5 4 3 2 1 0
Bit symbol
ADR59
ADR58
ADR57 ADR56 ADR55 ADR54 ADR53 ADR52
ADREG5H
(12ABH)
Read/Write R
After
reset
Undefined
Function
Stores upper 8 bits of AD conversion result.
9
8
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
7
6
5
4
3
2
1
0
Figure 3.11.6 Register for AD Converter
Channel
× conversion
result
ADREGxL
•
Bits 5 to 1 are always read as 1.
•
Bit0 is the AD conversion data storage flag <ADRxRF>. When the AD
conversion result is stored, the flag is set to 1. When either of the
registers (ADREGxH, ADREGxL) is read, the flag is cleared to 0.
ADREGxH