Connecting cable to sic and rj-45 connectors, Installing model 1005 repeater hub, Bnc connector/10base2 connection – Universal Scheu Company 1005 User Manual

Page 12

Advertising
background image

Model 1005 24-Port

Ethernet™Repeater Hub

10

9

Connecting Cable to SIC and RJ-45
Connectors

Connections between installed Model 1005 Repeater Hub SICs or
between a Model 1005 Repeater Hub SIC and a hub or terminal
device include:

Female AUI Connector/10Base5

Male AUI Connector/PC

RJ Connector/10BaseT

BNC Connector/10Base2

ST Connector/Fiber Optic

BNC Connector/10Base2 Connection

The thinnet coaxial card (E-CX-SIC) provides a BNC connector to
10Base2.

NOTE: Verify that coax
cables on Model 1005
Repeater Hub are terminated
properly at both ends.

(In a coax thinnet installation,
the first and last device in a
daisy-chain must be
terminated with a 50 ohm
terminator.)

Additionally, the 10Base2
segment must be grounded to
“earth ground” at one end.

50 ohm terminator

50 ohm terminator

Installing Model 1005 Repeater Hub

NOTE: Rackmount screws and clip nuts are NOT provided with the
Model 1005 Repeater Hub.

To install the Model 1005 Repeater Hub in 19-inch rack cabinet:

1. Locate four (4) screws (and clip nuts, if necessary) for each

Model 1005 Repeater Hub to be installed.

2. Carefully align the Model 1005 Repeater Hub between the 19-

inch rack mounting rails at the installation position.

3. Install two screws through right front bracket and two screws

through left front bracket, using clip nuts if necessary.

To install the Model 1005 Repeater on table or other flat surface:

1. Carefully turn Model 1005 Repeater Hub to side.

2. Install four (4) rubber feet (provided with repeater hub):

Remove protective paper from adhesive surface of rubber
foot.

Position rubber foot at bottom corner of repeater hub.

Secure rubber foot to repeater hub surface.

Repeat for remaining rubber feet.

3. Return Model 1005 Repeater Hub to upright position.

N E T W O R K S

T R A N S I T I O N

Advertising