PART B
FIGURE 8 -
(FIGURE 8 CONTINUED)

AIR SPACE
9 IN. MINIMUM

FACTORY-BUILT
CHIMNEY LENGTH

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

CHIMNEY LENGTH
FLUSH WITH INSIDE
OF FLUE

NONSOLUBLE
REFACTORY
CEMENT

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

CHIMNEY CONNECTOR
TO HEATER

MINIMUM CLEARANCE
9 IN. ALL AROUND

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY FLUE

SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY LENGTH

USE CHIMNEY MFRS. PARTS TO
ATTACH CONNECTOR SECURELY

AIR SP

A

C

E

TWO VENTILATED AIR
CHANNELS EACH 1 INCH.
CONSTRUCTED OF
SHEET STEEL.

PART C
FIGURE 8

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

MINIMUM 6 IN. GLASS
FIBER INSULATION ALL AROUND

24 GAUGE
VENTILATED THIMBLE WITH
TWO 1 INCH AIR CHANNELS

CHIMNEY THIMBLE

CHIMNEY FLUE

SHEET STEEL SUPPORTS

CHIMNEY SECTION

CHIMNEY
CONNECTOR

AIR SPACE
2 IN.

PART D
FIGURE 8

MINIMUM CLEARANCE
2 IN. ALL AROUND

CHIMNEY THIMBLE

1 IN. AIR SPACE TO
CHIMNEY LENGTH

MASONRY CHIMNEY CONSTRUCTED
TO NFPA 211

SHEET STEEL SUPPORTS
(24 GAUGE MIN. THICKNESS)

CHIMNEY FLUE

MINIMUM CHIMNEY CLEARANCES FROM MASONRY TO
SHEET STEEL SUPPORTS AND COMBUSTIBLES 2 IN.

CONNECTION OF CHIMNEY CONNECTOR TO A MASONRY CHIMNEY WHEN CHIMNEY CONNECTOR

DOES NOT PASS THROUGH A COMBUSTIBLE WALL

PART E - (Figure 8)
In addition to the methods shown by A, B, C, and D of Figure 8, a listed factory-built wall pass-through system
may be purchased and installed according to the instructions packaged with it to provide a safe method of
passing chimney connector through a combustible wall for a connection to a masonry chimney.

If the chimney connector does not have to pass through a combustible wall to get to a masonry chimney, simply connect
the chimney connector directly to the masonry chimney's chimney thimble as described and shown by parts C and D of
Figure 8. Remember, the chimney connector should extend into the chimney thimble to the innerface of the chimney flue
but not beyond; if the chimney connector is extended through the chimney thimble into the chimney flue, resistance to the
flow of smoke and gases up the chimney will occur; that flow resistance will have an adverse affect on the operation and
performance of the heater and venting system.

12

CHIMNEY CONNECTOR
TO HEATER

SOLID INSULATED, LISTED
FACTORY-BUILT CHIMNEY
LENGTH (12 IN. LONG MIN.)

CHIMNEY CONNECTOR
TO HEATER