For technical questions, please call 1-800-444-3353.

Item 98580

Sa

FE

ty

Op

ER

ati

O

n

m

aint

Enanc

E

SE

tup

troubleshooting

problem

possible causes

likely Solutions

Decreased output. 1. Not enough air pressure and/

or air flow.

2. Obstructed trigger.
3. Incorrect lubrication or

not enough lubrication.

4. Blocked air inlet screen

(if equipped).

5. Air leaking from loose housing.
6. Mechanism contaminated.

7. Vane wear or damage.

1. Check for loose connections and make sure that

air supply is providing enough air flow (CFM)

at required pressure (PSI) to the tool's air inlet.

Do not exceed maximum air pressure.

2. Clean around trigger to ensure free movement.
3. Lubricate using air tool oil and grease

according to directions.

4. Clean air inlet screen of buildup.

5. Make sure housing is properly assembled and tight.
6. Have qualified technician

clean and lubricate mechanism. Install in-line filter

in air supply as stated in Setup: Air Supply.

7. Replace all vanes.

Housing heats

during use.

1. Incorrect lubrication or

not enough lubrication.

2. Worn parts.

1. Lubricate using air tool oil and grease

according to directions.

2. Have qualified technician inspect internal

mechanism and replace parts as needed.

Severe air leakage.

(Slight air leakage

is normal,

especially on

older tools.)

1. Cross-threaded housing

components.

2. Loose housing.

3. Damaged valve or housing.
4. Dirty, worn or damaged valve.

1. Check for incorrect alignment and uneven gaps.

If cross-threaded, disassemble and

replace damaged parts before use.

2. Tighten housing assembly. If housing cannot tighten

properly, internal parts may be misaligned.

3. Replace damaged components.
4. Clean or replace valve assembly.

Follow all safety precautions whenever diagnosing or servicing the tool.

Disconnect air supply before service.