The connection of Model 35-R to an LP-Gas cylinder must
be made in a well ventilated area using the regulator and
hose assembly supplied with the appliance. DO NOT
attempt to adjust this regulator. It has been preset at the
factory to provide safe and proper operation of the
appliance. Use a 7/8” open end wrench to connect the
POL fitting (supplied with the LP regulator) to the LP-Gas
cylinder. Turn the POL nut in a counter-clockwise
direction (left hand thread) until tight. DO NOT use pipe
compound on POL threads.

The heater must be located at least six feet away from any
LP-Gas cylinder and must not be directed toward any LP-
Gas cylinder within 20 feet. If more than one heater is used,
they and the supply cylinders must be separated by at least
20 feet.

The gas supply must be turned off at the LP-Gas supply cylinder
when the heater is not in use.

When the heater is to be stored indoors, the connection
between the LP-Gas supply cylinder and the heater must be
disconnected and the cylinder removed from the heater and
stored in accordance with Chapter 5 of the Standard for the
Storage and Handling of Liquefied Petroleum Gases, ANSI/NF-PA
58 (U.S.), OR CAN/CGA B149.2 (Canada).

If connected to a permanently installed LP Gas supply system,
the system requires the use of a two-stage gas regulator
assembly which is normally provided by your LP-Gas dealer as
part of the LP-Gas supply system. Consult with your local LP-Gas
dealer for details concerning proper equipment and installation.

Piping must be clean and free from scale or burr.

Before attempting to ignite the appliance, all gas fittings and
connections must be thoroughly checked for gas leaks. Apply a
small amount of a mild soap and water solution to all fittings
and connections and observe for escaping bubbles. If any leaks
are detected, shut off the gas supply to the appliance
immediately. Wait a minimum of five minutes, repair the leak(s)
and retest for leakage. Dry all fittings and connections after
leak testing.

WARNING

NEVER USE A FLAME FOR GAS LEAK TESTING.

OPERATING INSTRUCTIONS

WARNING

:

IF YOU DO NOT FOLLOW

THESE INSTRUCTION EXACTLY, A FIRE
OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE,
PERSONAL INJURY, OR LOSS OF LIFE.

CAUTION:

THIS APPLIANCE IS

HOTDURING NORMAL
OPERATION. AVOID PHYSICAL
CONTACT.DO NOT MOVE OR
HANDLE DURING OPERATION
OR UNTIL COMPLETELY COOL.

CAUTION

DO NOT PLACE CLOTHING OR

OTHER COMBUSTIBLE
ATERIALS ON THIS APPLIANCE.

DO NOT operate this heater if any part has been under
water. Call a qualified service technician to inspect the
appliance and to
replace any part of the control system or gas
control valve which has been under water.

This appliance must be installed and operated only in
locations where the potential for physical damage to the
appliance is reduced to a minimum. The owner/operator of
this appliance must ensure that precautions are taken to
protect the appliance from physical damage.

LIGHTING AND SHUT-DOWN

Lighting the Heater:

1.

Before attempting to light the heater, smell all
around the heater area for gas. Be sure to smell
next to the floor because LP-Gas is heavier than
air and will settle on the floor. Turn on the gas
supply to the appliance and check all fittings and
connections for gas leaks using a mild soap and
water solution. Read enclosed Odor Fade and
Propane Sheet for additional information about
detecting propane leaks. NEVER use a match to
check for gas leaks. Should a gas leak occur, shut
off the gas supply to the appliance immediately.
Wait a minimum of five minutes before repairing
the leak.

2.

Use only the fuel intended for this appliance.
Check the appliance rating plate for the correct fuel
information.

3.

Turn off the main gas supply to the appliance. Wait
five minutes.

4.

Turn on the main gas supply.

5a. Depress and turn Control Knob counterclockwise to

“Pilot” position and hold for 1-2 minutes. This may take
longer to purge air from the supply hose depending on
the length of the hose being used.

Depress red spark ignition button to light pilot flame
(repeat until pilot lights) and continue to hold Control
Knob at “Pilot” positionfor 30-60 seconds to enable
Pilot Light Safety System.

Fully turn Control Knob to “Hi” position to light burner. or...

5b. With a lighted match held to the burner face, depress

and hold the reset button. After the burner ignites,
hold the reset button depressed for about one minute
or until the burner stays lit when the reset button is
released. DO NOT light the gas at the burner
orifice. DO NOT face heater when attempting to
light. Always stand to the side of the unit when
lighting.