Universal Scheu Company SPC-150T User Manual

Operating instructions, Models 150-fast, Propane construction

Advertising
background image

!

GENERAL HAZARD WARNING:

FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS OR DAMAGE
FROM HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING,
AND/OR ELECTRICAL SHOCK.

ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS HEATER.

IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL,
LABELS, ETC. CONTACT THE MANUFACTURER.

OPERATING INSTRUCTIONS

HEATER

HEATERMODEL 80-FAP

YOUR SAFETY IS IMPORTANT TO YOU AND TO OTHERS,
SO PLEASE READ THESE INSTRUCTIONS BEFORE YOU
OPERATE THIS HEATER.

RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.

!

PROPANE

CONSTRUCTION

National-Riverside

Universal

MODEL SPC-150T

SPC

ALL-PRO

FORCED AIR

150,000 BTU/HR

HEATER SPECIFICATIONS - 150

Type of Gas

For Use with Propane Gas Only

Input Rating

150,000 BTU/hr

Fuel Consumption

7 Lbs/hr

Gas Supply Pressure
to Regulator

Max: Bottle Pressure
Min: 5 psig

Regulator Out

11" W.C.

Fuel Orifice Size

1.00 mm Drill - 18 Holes

Electrical Input

115V, 60Hz 10, 4a

Minimum Operating Voltage

100V

Fan

3000 rpm, 450 cfm

Average Air Temp Rise

Approx. 300

o

F

Ignition

Direct Spark, Interrupted Type

Primary Flame Control

Solid State, 10-15 second Timing

High Temperature Limit Control

240

o

F

Minimum Ambient Temp. Rating

0

o

F

Size (Length x Width x Height)

26" x 9" x 16"

New Weight

32 lbs.

Shipping Weight

34 lbs.

MODELS 150-FAST