Setting DIP Switches

NOTE: Please be careful when changing the DIP switch settings. Carefully use a pointer on the DIP switch you are

going to change.

DO NOT use a screw driver or apply excessive force.

DIP Switch Functions

DIP

Switch

Function

Switch

Switch

Switch

Switch

Notes

1,2,3,6

Communication Interface

SW1

SW2

SW3

SW6

RS232

Off

Off

Off

Also set 4 & 5

IrDA

On

On

Off

Also set 4 & 5

Bluetooth

Off

On

On

38,400 Baud Rate

IR Direct Mode

On

On

Off

On

9600 Baud Rate

4 & 5

COM 1 & 2 - Baud Rate

SW4

SW5

RS232 Rate

38,400

Off

Off

Bluetooth

19,200

Off

On

9600

On

Off

2400

On

On

4 & 5

COM 2 – IrDA Baud Rate

SW4

SW5

IrDA Baud Rate

9600

Off

Off

Fixed

9600 - 38.4 Baud

On

Off

Variable

6 & 7

COM 1 & 2 - Parity Bits

SW6

SW7

No parity

Off

Off

Odd parity

On

Off

Even parity

On

On

8

Auto Power Save

SW8

Power save disabled

Off

Manual On/Off

Power save enabled

On

Auto Power Down

NOTE: In order for changes to the DIP switch configuration to take effect, the printer’s power must be reset.

Communication

• The MP200 has two serial communication UARTs. It is able to support two

modes of communication simultaneously – either RS232 and IrDA (If DIP switch 1

is on) or RS232 and Bluetooth (If DIP switch 1 is off and DIP switch 5 is on).

• DIP switch 1 is used to control the RS232 port. If the switch is turned on the

RS232 port is disabled and if it is turned off the RS232 port is enabled. If RS232

interface is not required, disabling the port will save battery power.

Serial Communication Specification

• The RS232 interface signals for the MP200 printers are terminated on a

6-pin RJ type data connector located on the side of the printer.
• Six connections are provided from the serial interface to the host computer. The

serial interface signals and pin outs on the RJ connector, and the connector

pin locations are shown below.
• A minimum of two connections are required for operation: RXD – pin 3 and Common

– pin 1.

The communication parameters: baud rate, data bit and parity must be set the same

as the host device settings.

RJ45 Connector Pin #

Communication Interface

Signal Name

3

RS232 from host (Input)

RXD

2

RS232 from printer (Output)

TXD

6

Request to send from host (Input)

RTS

4

Clear to send from printer (Output)

CTS

1, 5

Logic common

COM

!

!