Troubleshooting, Caution – UltraViolet Devices MP22A User Manual

Page 13

Advertising
background image

13

Problem Possible

Cause

Corrective

Action

No electrical power…

Verify that the purifier is connected to a live power source.

Ballast

Disconnect the purifier from utility power. Replace lamp.

Lamp-out Protection

The purifier must remain disconnected from power for

(MP16A, MP22A & MP36C)

two (2) minutes to reset.

Cracked or broken

Shut down purifier, drain, and replace quartz sleeve.

quartz sleeve…

See “Quartz Sleeve Cleaning or Replacement” in the
Maintenance” section.

Water leaking into/from

Quartz sleeve sealing

Shut down purifier, drain, and remove static gland nut,

purifier.

o-ring (s) worn, damaged…

replace sealing o-ring. See “Quartz Sleeve Cleaning or
Replacement
” in the “Maintenance” section.

Poor, or loose, connections

Tighten suspect connection or fitting; or shut down

or fittings…

purifier, drain, and remove fitting or connection.
Clean threads; reapply thread sealing tape and reinstall.

Quartz sleeve fouled…

Clean quartz sleeve, see “Quartz Sleeve Cleaning
or Replacement
” in the “Maintenance” section.

Sensor Probe, if equipped,

Clean lens or Quartz Rod, see “Optional Ultraviolet

lens fouled…

Monitor Sensor Probe Cleaning” in the “Maintenance
section.

Poor purifier performance

Germicidal lamp output

Replace lamp, as it nears its end of life (EOL). See

AND/OR Low UV intensity

depreciating… “Lamp Replacement” in the “Maintenance” section.

(As indicated on Optional

Germicidal lamp not

Replace lamp. See “Lamp Replacement” in the

Guardian

functioning… “Maintenance” section.

Ultraviolet Monitor).

Low input voltage…

Verify input voltage to purifier.

Change in water quality…

Have water tested to confirm that it does not exceed
maximum recommended concentration levels for use
with this purifier.

TROUBLESHOOTING

CAUTION:

Always disconnect power to the water purifier, before performing any service.

IMPORTANT: This unit is to be serviced ONLY by qualified, and appropriately licensed, personnel.

Table 3 - Troubleshooting

!

Purifier not operating.