Installation

VENT TERMINATION CLEARANCES:

A)

Minimum 4-foot clearance below or beside any door or window that opens.

B)

Minimum 1-foot clearance above any door or window that opens.

C)

Minimum 3-foot clearance form any adjacent building.

D)

Minimum 7-foot clearance from any grade when adjacent to public walkways.

E)

Minimum 2-foot clearance above any grass, plants, or other combustible materials.

F)

Minimum 3-foot clearance from an forced air intake of any appliance.

G)

Minimum 2-foot clearance below eves or overhang.

H)

Minimum 1-foot clearance horizontally from combustible wall.

Must be a minimum of 36-inches above the roof and 24-inches above the highest point or the roof within 10-feet.

FIGURE 6

VENT TERMINATION CLEARANCES

H

A

B

C

I

F

D

A

F

E