Installation – United States Stove Company 6110 User Manual

Page 6

Advertising
background image

6

USSC

INSTALLATION OPTIONS

Read this entire manual before you install and use your Multi-Fuel Furnace. Failure to follow instructions
may result in property damage, bodily injury, or even death!

(See specific installation details for clearances and other installation requirements)

As a Primary Furnace—the unit functions independently of any other system. The “Room Air” blowers will come on
when the plenum and Exhaust temperatures reach a preset point on the furnace’s circuit board (PCB).

As a Secondary (Add-On) Furnace—the unit aids an existing gas/electric furnace helping cut down on operation time.

It is recommended that only a authorized technician install your Multi-Fuel Furnace, preferably an NFI certified specialist.

М

М

М

М

М

Installation

IMPROPER INSTALLATION: The manufacturer will not be held responsible for damage caused by the mal-
function of a furnace due to improper venting or installation. Call (800) 750-2723 and/or consult a professional
installer if you have any questions.

FLOOR PROTECTION

This unit must be installed on a non-combustible floor surface. If a floor pad is used, it should be UL listed or equal. The
floor pad or non-combustible surface should be large enough to extend a minimum of 6-inches in front, 6-inches on each
side, and 1-inch behind the furnace for horizontal termination.

Floor protection must extend under and 2-inches to each side of the chimney tee for an interior vertical termination.

A Floor Protector of 1 inch thick is recommended for this installation.

ADDITIONAL ITEMS NEEDED FOR INSTALLATION

• UL listed 3 inch or 4 inch (Depending on application) “PL” pellet venting exhaust system.

• Air distribution duct work. Transition from 4.5 inch x 18.5 inch rectangle to 10 inch round is provided.

• Air filter (Optional). Size: 10 x 20 x 1

• Floor Protection (If not installed on a non-combustible floor)

• Air return vent from the house to the room where furnace is installed.

• Fresh air for combustion if located in a small, tightly constructed room.