CLEARANCES TO COMBUSTIBLES
It is of utmost importance that the clearances to combustible materials be strictly adhered to during
installation of the stove. Refer to the tables below :
• Floor to ceiling height must be at least 7’ (84”) in all cases.
• Do not place any combustible material within 48” of the front of the unit.
• The clearance between the flue pipe and a wall are valid only for verticle walls and for verticle flue
pipe.
• The flue pipe must not go through roof trussing, an attic, a closet, a floor, a combustible partition,
or similar spaces.
• A flue pipe crossing a combustible wall must have a minimum clearance of 18”.
• To reduce flue clearances from combustible materials, contact your local safety department.
Single Wall Pipe (Double Wall Pipe)
Model
A
B
C
D
E
F
2000
20(14)
22(20)
22.5(16.5)
32(30)
12(11)
22(21)
2500
12
20
16
30
10.5
20