CLEARANCES TO COMBUSTIBLES

It is of utmost importance that the clearances to combustible materials be strictly adhered to during

installation of the stove. Refer to the tables below :

• Floor to ceiling height must be at least 7’ (84”) in all cases.
• Do not place any combustible material within 48” of the front of the unit.
• The clearance between the flue pipe and a wall are valid only for verticle walls and for verticle flue

pipe.

• The flue pipe must not go through roof trussing, an attic, a closet, a floor, a combustible partition,

or similar spaces.

• A flue pipe crossing a combustible wall must have a minimum clearance of 18”.
• To reduce flue clearances from combustible materials, contact your local safety department.

Single Wall Pipe (Double Wall Pipe)

Model

A

B

C

D

E

F

2000

20(14)

22(20)

22.5(16.5)

32(30)

12(11)

22(21)

2500

12

20

16

30

10.5

20