Ultimate Products SGX User Manual

Page 6

Advertising
background image

2319 Laurelbrook Street, Raleigh, NC 27604 · (800) 542-7221 · FAX (919) 834-4526 · www.ultimate-products.com

- 5 -

A.2

PACKAGING AND SHIPPING INFORMATION (CONT.)

Options:

Fresh air Intake (Mounted to Burner/Control)

Fan Vent Adapters- Vertical and Horizontal

Thermostat

Flexible Gas Connector

Ball Valve

Vent Hoods

Hanging Assembly (chain, etc.)


Shipping packages for individual projects will be boxed and crated as outlined

on the specific bill of lading.


A.3

MOUNTING CLEARANCES

The heater should be positioned so that clearances from combustible materials
will meet or exceed those shown in the following table. Also, ensure that there is
at least 6” clearance on all sides of burner for service access and for free flow of
combustion air. When heater is angle mounted, the burner/control assembly
must remain horizontal.

Minimum Clearances To Combustibles In Inches

Model

Input – BTU / HR

A

B

D

E

GH / ER / AL / SC 12

40,000

43

20

4

6

GH / ER / AL / SC 15

50,000

66

20

*

6

GH / ER / AL / SC 18

60,000

66

20

*

6

GH / ER / AL / SC 22

75,000

66

20

*

6

GH / ER / AL / SC 29

100,000

72

30

12

6

GH / ER / AL / SC 38

130,000

72

30

12

6

GH / ER / AL / SC 44

150,000

93

36

12

6






Advertising
This manual is related to the following products:

SA, AL, CW, ER, SC