CONNECTING THE WATER SUPPLY

On Ice Maker models BI 2015 and Combo 2075FF, install a 1/4 inch
outside diameter copper water line (not supplied with unit) from the
nearest COLD water pipe. When connecting the water supply, follow
these guidelines:

• Review the local plumbing codes before you install the unit.
• In most instances, the cold water supply will come from the

basement through a hole in the floor.

• The water pressure should be between 15 and 150 psi.
• Install a shut-off valve in the 1/4 inch outside diameter supply

line.

• Connect sufficient tubing to the unit to allow the unit to be

moved for cleaning and servicing. However, make certain that
the tubing is not pinched or damaged during installation.

• U-Line recommends the use of copper tubing for installation.

Figure 3

7

1. Locate the compression fit-

ting and ferrule packed in the
unit. Slide the compression
fitting and ferrule over the
1/4 inch outside diameter
water supply line. Do not use
thread sealing compound or
tape.
Using two wrenches,
tighten the compression fit-
ting on the supply line (see
Figure 3).

UL134

2. Carefully bend the water supply

line into position and connect
the line to the solenoid valve
(see Figure 4). Avoid kinking
the water supply line.

UL103

WATER

CONNECTION