USRobotics V.34 User Manual

Page 113

Advertising
background image

COURIER HIGH SPEED MODEMS

Summaries and Tables B-19

Register

Default

Function

S15

0

Bit-mapped register. To set the register,
see the instructions for S13.

Bit Value Result

0

1

Disable the modem's extra
high-frequency equalization if
it causes problems on shorter-
link calls

HST-modems only

1

2

Disable online fallback

2

4

Disable 450 bps back channel

HST only

3

8

Reset non-ARQ mode
Transmit buffer from 1.5K
bytes to 128*

4

16 Disable MNP Level 4; retrans-

mitting the larger Level 4 data
blocks may be a problem if you
expect a great number of
errors during a call

5

32 Set backspace key to delete

6

64 Some earlier 2400 bps MNP

modems, not made by U.S.
Robotics or Microcom, were
not fully compatible with the
MNP protocol. If you have
difficulty making a successful
2400 bps MNP connection with
a remote MNP modem, it may
be because of this incompati-
bility. Set S15 to 64 and try
again to make the connection.

7

128 Custom applications only

* The default 1.5K byte non-ARQ buffer allows data transfer
with X- and Ymodem-type file transfer protocols without using
flow control.

The 128-byte option allows remote users with slower modems
to stop data you're transmitting from scrolling off their screens.
When remote users send your computer an XOFF (<Ctrl-S>)
and you stop transmitting, the data in transit from your
modem's buffer doesn't exceed the size of their screen.

Advertising