Electrical specifications, Leveling information, 7 prepare power supply – U-Line BI-95 User Manual

Page 9: 8 level the unit

Advertising
background image

02/2005

9

www.U-LineService.com

BI-95 Ice Maker

Electrical Specifications

CAUTION

Electrical installation must observe all state and local
codes. This unit requires connection to a grounded (three-
prong), polarized receptacle that has been placed by a
qualified electrician.

The unit requires a grounded and polarized 115 VAC,
60 Hz, 15A power supply (normal household current).
An individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.

See Figure 19 for recommended receptacle location.

WARNING

SHOCK HAZARD — Electrical Grounding Required.

• Never remove the round grounding prong from

the plug and never use a two-prong grounding
adapter.

• Never use an extension cord to connect power to

the unit.

Go on to 8 Level the Unit.

Leveling Information

IMPORTANT

It is extremely important that the unit sits on a level
surface, as it does not have feet levelers. If it is not level,
the ice mold will not fill evenly.

Use a level to check the
levelness of the unit from
front to back and from side
to side. Level should be
placed along top edge and
side edge as shown (see
Figure 20). Go on to
9 Install the Unit.

7 Prepare Power Supply

18-1/2"

Minimum

1-1/2"

7"

Figure 19

8 Level the Unit

Check

Level

Figure 20