Locating the heater, Fig. 2 fig. 4, Fig. 3 – United States Stove Company 2827 User Manual

Page 4

Advertising
background image

LOCATING THE HEATER

AS A LOCATION IS SELECTED,
KEEP THE FOLLOWING IN MIND:

1. The chimney connection should be as
possible. The heater must have its own chim-
ney. Do not connect this unit to a chimney flue,
serving another appliance. If there is no chim-
ney near where you wish to place the heater,
you can use a UL 103HT Residential Type and
Building Heating Appliance Chimney (Fig. 5
&6).

2. Place the heater on solid masonry or solid
concrete. When the heater is used on a com-
bustible floor protector of one layer of 3/8"
millboard having a thermal conductivity of
K=0.84 BTU in./ft. 2 hr. Deg. F with 28-gauge
sheet metal or a UL Listed floor protector. Have
the floor protector extend 16" beyond the door
side of the heater and under the connector pipe
in the back.

3. Check Figures 2, 3, and 4. Be sure you have
the clearances shown from the heater and the
connector pipe to combustible surfaces. If you
have a solid brick or stone wall behind your
heater, you can place the heater as close as
you wish to the wall. If the wall is only faced with
brick or stone, treat it as a combustible wall.

NOTE: BEFORE FIRING

HEATER

Slide firebricks toward the rear

so no gaps remain between

them.

CAUTION:

Keep furnishings and other

combustible materials away

from the heater.

4

REPAIR PARTS LIST - MODEL 2827 (SEE PAGE 18)

AUTOMATIC COAL BURNING CIRCULATOR

17

Fig. 2

Fig. 4

Key No.

Description

Qty.

Part No.

1

Shaker

1

40045

2

Second Heat Shield Assembly

1

22030

3

Heat Shield

1

22110

4

Draft Damper Hinge Pin

1

17200

5

Draft Damper Frame

1

40075

*

1/4-20 x 3/4 MS

4

83086

*

1/4-20 Kep Nut

4

83250

6

Base

1

67859

7

Draft Control Damper

1

67132

8

Clip

1

83818

9

Coal Grate

1

40101

10

Grate Support

2

22536

*

1/4-20 x 3/4 MS

8

83086

*

Nut 1/4-20 Kep

8

83250

11

Firebrick

10

89066

12

Firebox

1

67858

13

Front & Back Liner

3

40100

14

Flue Collar

1

40246

15

Flue Collar Gasket

1

88032

16

Firebrick Retainer

2

40132

*

1/4-20 x 1

6

83227

*

1/4-20 Kep Nut

6

83250

*

Smoke Curtain Bracket

2

22171

*

1/4-20 Kep Nut

2

83250

*

Machine Screw (1/4-20 x 3/4 PH)

2

83086

17

Hinge Pin

1

83872

18

Smoke Curtain

1

22090

19

Coal Grate Frame

1

40102

20

Feed Door Assembly

1

68605

21

1/4-20 Kep Nut

2

83250

22

Draft Wheel

1

40056

23

Machine Screw (1/4-20 x 1)

1

83227

24

Door Handle

2

40091

25

Wood Handle

1

89523

26

Feed Door Rope Gasket

45"

88033

27

Ash Door Assembly

1

67781

28

Two-Step Latch

1

22434

29

Washer, Flat

2

83045

30

1/4-20 Kep Nut

2

83250

31

Ash Door Gasket

29"

88033

32

Latch

1

22108

33

Ash Pan

1

67444

*

1/4-20 x 3/4 MS, SL, FL,2

6

83086

*

1/4-20 Kep Nut

6

83250

34

Latch Spacer

1

21467

35

Hinge Pin (Long)

1

83114

*

NOT SHOWN

Fig. 3

25"

35"

16"

26"

54"

19 1/4"

36"

4 3/4"

NOTE: DASHED LINES SHOW
STRAIGHT UP AND THROUGH
THE WALL INSTALLATION

17"

32 1/4"

16"

FLOOR PROTECTOR
(TOP VIEW)

SIDEWALL

NON-COMBUSTIBLE
CONSTRUCTION IN
ACCORDANCE WITH
NFPA 211

12"

12"

WONDERCOAL

Advertising