Document clamp open –8, Self test –8, Document validation –8 – Unisys E-@CTION EFP9800 User Manual

Page 212: Receipt/journal print –8

Advertising
background image

EF4270 Emulation Commands

9–8

3255

4073–002

Document Clamp Open

Opens the platen. Any forms still in the printer may fall back into the validation
station when the platen is opened. This command enables the Receipt/Journal
paper feed and disables the Slip/Validation paper feed.

Hexadecimal Decimal ASCII

1B 0C

27 12

ESC FF

Self Test

Clears all data in the print buffer and prints the current configuration
parameters. This functions the same as the general print test See “General Print
Test” in “Chapter 3: Diagnostics” for more information.

Hexadecimal Decimal ASCII

1B 13

27 19

ESC DC3

Document Validation

Opens the platen. Once a form is detected, the platen will automatically close.
This command enables the Slip/Validation paper feed and disables the
Receipt/Journal paper feed.

Hexadecimal Decimal ASCII

1B 17

27 23

ESC ETB

Receipt/Journal Print

Closes the platen. The 1B 5A version of the command closes the platen when no
form has been detected. This command enables the Receipt/Journal paper feed
and disables the Slip/Validation feed.

Hexadecimal Decimal ASCII

1B 1A

1B 5A

27 26

27 90

ESC SUB

ESC Z

Note: The ASCII SUB character cannot be sent by some PC applications. In

that case, use the following version of the Receipt/Journal Print
command.

Advertising