Victory Refrigeration VBC-480 User Manual

Page 2

Advertising
background image

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice.

Victory Refrigeration, Inc.

Remote Roll-In Blast Chiller

CHARACTERISTICS

VBC-480

VBC-660

Capacity (lbs./90 mins.)

480 lbs

660 lbs

Width, Overall

57.95”

57.95”

Depth, Overall

92.7”

92.7”

Depth, Door Open 90º

120.25”

120.25”

Height with Floor

101.7”

101.7”

Height without Floor

98.2”

98.2”

Clear Door Width

27.5”

27.5”

Clear Door Height

73.8”

73.8”

No. of Carts (Optional)

2

2

Cabinet Voltage

208-230/60/3

208-230/60/3

Feed Wires (with Ground)

3

3

Total Amperes

20

20

Note: The self-contained refrigeration system is top mounted for the storage cycle only. This avoids short cycling of the stand

alone condensing unit when in the +38°F storage mode. All roll-in models require remote refrigeration.

Crated Dimensions and Weights

Height

Width

Depth

Weight

VBC-480 72”

90.5”

59”

1158 lbs

VBC-660 72”

90.5”

59”

1158 lbs

†Shipped on 2 skids, each of this weight. Add 110 lbs per roll-in rack ordered.

Storage Refrigeration Data

Refrigerant Compressor BTUH*

VBC-480

R-134a

.75 H.P.

4759

VBC-660

R-134a

.75 H.P.

4759

*BTUH @ 100

o

F. Ambient, +25

o

F. Evaporator

Remote Blast Chilling Refrigeration Data

Refrigerant Liquid Line Suction Line BTU/H*

Size

Size

VBC-480 R-404A .5 (X2)

1.125 (X2) 60,000

VBC-660 R-404A .5 (X2)

1.125 (X2) 72,000

*BTUH @ 90

o

F. Ambient, +5

o

F. Evaporator

Dimensional tolerance ± .25” Metric dimensions (mm)

Top View

Front View Without Insulated Floor

Copyright June 2009

Printed in U.S.A. 063009

NOTE: If cabinet is located
directly against wall an all around
clearance of 2” is required, and a
minimum clearance of 10” under
ceiling.

Insulated floor adds 3.5” in
height.

We reserve the right to change
specifications and product
design without notice. Such
revisions do not entitle the
buyer to corresponding
changes, improvements,
additions or replacements for
previously purchased
equipment.

Advertising