Troubleshooting – Appendix C

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Inverter Alarm Sounds

Low battery voltage

Check Battery Level Display

and recharge battery if low

Inverter will not operate

Battery below 10.0 Volts

Charge battery

No LEDs lit

Inverter shuts down,

Overloaded inverter

Reduce AC load and reset

Red LED lit

inverter

Inverter shuts down,

Overheated Inverter

Let inverter cool 15 minutes,

Red LED lit

reduce AC load and reset

Inverter shuts down,

Bad connection on battery

Clean all contacts, tighten

Red LED lit

cover posts or battery

the post connectors and

terminal connections

battery terminals

Inverter will not operate,

Internal failure of inverter

Call Vector Technical Support-

No LEDs lit, battery is charged

Return to Vector for service

No inverter output.

GFCI outlet assemble is tripped

RESET GFCI assembly

Inverter Green LED lit,

battery charged and

no alarms sound.

Battery is charged but

Loose battery connections

Clean all contacts, tighten

won’t handle large loads.

the post connectors

and battery terminals

Fluorescent Lamp does not light

DC plug not fully inserted

Insert plug in socket and

in DC socket.

rotate to make good contact

Fluorescent Lamp does not light

Dead battery

Charge battery

Fluorescent Lamp does not light

Tube burned out or cracked

Call Vector Technical Support

- Return to Vector for service

Compressor is laboring and slow

Low battery voltage

Check Battery Status Display

and recharge battery

Compressor is laboring and slow

Low battery, bad connections

Recharge battery, clean and

(external DC Source)

tighten connections

Compressor does not operate

Compressor motor failure

Call Vector Technical Support

but fan is turning

- Return to Vector for service

Noise in Radio or TV

Appliance antenna too close

Move antenna away from

close to inverter

inverter use shielded cable

Contact Vector Technical Support toll free (866) 584-5504.