Vent-a-Hood Under Cabinet Range Hood SL6 User Manual

Under cabinet range hood specifications, Sloped bottom 6” 9

Advertising
background image

WID

TH

2”

9”

19 ½”

12”

6”

Sloped

Bottom

6”

9”

UNDER CABINET RANGE HOOD SPECIFICATIONS

Electrical/Mechanical Specifications For Blower Units

SL6/SLH6

SL6/SLH6 “H” in part number indicates halogen lighting. WL-1 warming lights are available on selected
models.

SL6/SLH6 SIDE VIEW

Connection Diagrams (30”- 48” Widths)

Recommended

Mounting Height*

VP562/VP563

transition

centers outlet

over top of hood

*Exceeding recommended

mounting height may

compromise performance.

Model

B100 Single

Volts

Amps

RPM

CFM

[email protected]

Equivalent CFM

CFM

[email protected]

CFM

[email protected]

CFM

[email protected]

Minimum Round

Duct Size

Square

Inches

#

B200 Dual

115

115

1.7

3.4

1550

1550

300

600

450

900

286

572

270

540

240

480

6” (or equivalent)

8” (or equivalent)

28

50

Note: Add 2.5 amps for each warming light and 0.5 amp for each halogen light. Hood is available with fluorescent light (1 for each single or dual blower) or with halogen lights (2 lights: 30” - 41”, 3 lights: 42” - 53”, 4 lights: 54” - 66”, +1 light for each 16” if over 66”).
Because the Magic Lung

®

uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung

®

blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently

than other filtration systems. When comparing the Magic Lung

®

with other blower units made by other manufacturers, use the “Equivalent CFM”.

*

*
#

Connection Diagram (42” - Wider)

Connection Diagram (48” - Wider)

300 CFM B100 Single Blower 600 CFM B200 Dual Blower

(Top View)

(Top View)

900 CFM B200 Dual & B100 Single Blower

(Top View)

1200 CFM Double B200 Dual Blowers

(Top View)

6” Outlet

Vent

Hole

3 ¼”

Electrical

Centerline

of Hood

Wall Side

1 ¾”

1 3⁄8”

5 ¼”

Electrical

1 ¾”

Centerline

of Hood

8” Outlet

Vent

Holes

5 ¼”

5 ½”

Wall Side

8” Outlet

6” Outlet

5 ¼”

Wall Side

Vent

Holes

Centerline

of Hood

Electrical (2)

5 ½”

7 5⁄16”

1 7⁄8”

7 5⁄16”

1 ¾”

11”

11”

5 ½”

5 ½”

Wall Side

5 ¼”

1 ¾”

Electrical (2)

8” Outlet

Vent

Holes

8” Outlet

Centerline

of Hood

10” Round

10” Round

8” Round

17 ½”

2”

8” Round

6” Round

12” Round

12” Round

16 ½”

8” Round

8” Round

8” Round

3”

VP562 Transition (Optional) For B300

(B200 Dual Blower & B100 Single Blower)

VP563 Transition (Optional) For B400

(Double B200 Dual Blowers)

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Rev. 04/08

UL

C

US

R

36”

8’ Ceiling

21”-24”

6”

Soffit

Cabinets

10” OR 12”

Round

Advertising