background image

107887

For more information, visit www.desatech.com

For more information, visit www.desatech.com

8

THERMOSTAT SENSING BULB

(Thermostat Models Only)

The thermostat sensing bulb has been placed inside the heater for
protection during shipping.

Locating Thermostat Sensing Bulb (for thermostat
applications)

1.

Remove front panel of heater (see Figure 7).

2.

Locate thermostat sensing bulb just under burner assembly.

IMPORTANT:

Attach thermostat sensing bulb to back of heater for

proper operation.

Attaching Thermostat Sensing Bulb

1.

Remove thermostat sensing bulb from holders inside heater.
Route through slot opening in bottom of heater.

2.

Place clamp on thermostat sensing bulb as shown in Figure 5.
Clamp is provided in hardware package.

3.

Snap clamp into upper mounting hole as shown in Figure 5.
Mounting hole is located on lower left edge on back of heater.
Make sure the thermostat sensing bulb is pointing up.

INSTALLATION

Continued

INSTALLATION

Thermostat Sensing Bulb
Installing Heater To Wall

INSTALLING HEATER TO WALL

Mounting Bracket

Locate mounting bracket in heater carton. Remove mounting bracket
from heater carton.

Figure 6 - Mounting Bracket

Figure 5 - Attaching Thermostat Sensing Bulb

Figure 7 - Removing Front Panel Of Heater

Removing Front Panel Of Heater

1.

Remove the four painted screws, two on each side of front panel.

2.

Pull bottom of front panel forward, then out.

3.

Remove any remaining packaging materials.

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket
to wall. These two holes are 14 inches apart from their centers.
Attach mounting bracket to wall in one of two ways:

1.

Attaching to wall stud

2.

Attaching to wall anchor

Attaching to Wall Stud:

This method provides the strongest hold.

Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor:

This method allows you to attach

mounting bracket to hollow walls (wall areas between studs) or to
solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will
provide a secure hold for the mounting bracket.

WARNING: Maintain minimum clearances shown

in Figure 8, page 9. If you can, provide greater clear-
ances from floor and joining wall.

Marking Screw Locations

1.

Tape mounting bracket to wall where heater will be located.
Make sure mounting bracket is level.

Clamp

Thermostat Sensing Bulb

Advertising
This manual is related to the following products: