Viewsonic cd3200 iii – VIEWSONIC VS11857 User Manual
Page 53

ViewSonic
CD3200 iii
Set-Function description:
Length:
Total bytes of message = 5 ASCII (35H) excluding “CR”
Command:
Function command code: One byte ASCII code
Value[1~3]:
Three bytes ASCII that defines the value
Set-Function format:
Name
Length Command Value1 Value2 Value3 CR
Byte Count
1 Byte
1 Byte
1 Byte
1 Byte
1 Byte 1 Byte
Bytes order
1
2
3
4
5
6
All Set-Function from PC to Monitor (ASCII)
Name
Length Command Value1 Value2 Value3 CR
Byte Count
5
1 Byte
1 Byte 1 Byte 1 Byte 00D
Bytes order
1
2
3
4
5
6
Example: Set Mute-ON command (ASCII)
Name
Length Command Value1 Value2 Value3 CR
Byte Count
5
6
0
0
0
00D
Bytes order
1
2
3
4
5
6
Example: Set Mute-OFF command (ASCII)
Name
Length Command Value1 Value2 Value3 CR
Byte Count
5
6
0
0
1
00D
Bytes order
1
2
3
4
5
6
Example: Set Tint to -50 command (ASCII)
Name
Length Command Value1 Value2 Value3 CR
Byte Count
5
‘
-
5
0
00D
Bytes order
1
2
3
4
5
6