pIpE INSTAllATION

4. Use 6” round black stove pipe, not galvanized

stove pipe. Secure pipe sections with three
(3) sheet metal screws in each stove pipe and/
or elbow joint to firmly hold the pipe sections
together.

DO NOT CONNECT THIS STOVE

TO ANY AIR DISTRIBUTION OR DUCT

SYSTEm.

5. R e c h e c k c l e a r a n c e s f r o m t h e s t o v e ,

connector stove pipe, and corner clearanc-
es using the illustrations (figure 1 & 2) and

lOCATINg STOvE continued…

1. The smooth end of the stovepipe fits over the cast

iron collar. To attach, simply hand form the smooth
end of the round stove pipe into an oval shape (fig.
4). Drill & secure with a minimum of three (3) sheet
metal screws.

2. Horizontal pipe runs must slope upwards

towards the chimney at least 1/4” per foot of hori-
zontal run.

3. You must have at least 18 inches of clearance be-

tween any horizontal piping and the ceiling.

4. The pipe cannot extend into the chimney flue (figure

5).

5. Secure pipe/elbow sections with three (3) sheet

metal screws at each joint to make the piping
rigid.

Fig. 5 – Stovepipe/Flue Connections

CORRECT wRONG wRONG

CAUTION: kEEP FURNISHINGS AND OTHER
COmBUSTIBLE mATERIALS AwAY FROm THE
STOVE.

36"

36"

CORNER CLEARANCES

mINImUm CLEARANCES

TO COmBUSTIBLE SURFACES

6. It is recommended that no more than two (2)

90° bends be used in the stovepipe installa-
tion. The use of more than two 90° bends may
decrease the amount of draw and possibly
cause smoke spillage. Where possible, use only
corrugated (nonadjustable) elbows. These
provide a better seal.

7. The chimney connector must not pass through an

attic or roof space, closet, or any concealed space, or
floor, ceiling, wall or combustible construction.

your local building codes or fire protection
ordinances.

NOTE: Drywall faced with brick or stone should
be considered a combustible surface.

6.

D O N O T I N S TA L L T H I S S T O V E

IN A mOBILE HOmE OR TRAILER.

(NO EXCEpTIONS)

7. The clearances provided are minimum

dimensions. Installation of this stove must
comply with your local building code rulings.

8. This stove is NOT a UL listed stove.

Fig. 4 – Hand-form pipe to fit stove collar

NOTE: STOVE PIPE IS NOT INClUDED.
TO PURCHASE PIPE, VISIT YOUR LOCAL
HARDwARE, HOmE OR BUILDING CEN-
TER. SEE “LOCATING STOVE” PAGE 3 FOR
ADDITIONAL SPECIFICATIONS.

Unit to Sidewall ....................... 36 inches
Unit to Backwall ...................... 36 inches
Unit Corner to wall .................. 36 inches
Pipe Connector to Ceiling ...... 18 inches

Fig. 3 – Top View

Minimum Corner Clearances from

Combustible Surfaces