Tested and certified by NSF International against ANSI/NSF Standards
42 & 53 in models RWFFR for the reduction of:
Standard No. 42

Standard No. 53

Aesthetic Effects:

Health Effects:

Taste and Odor Reduction

Chemical Reduction Unit

Chlorine Taste & Odor

Lead, Atrazine, Lindane,

Mechanical Filtration Unit

Benzene, Carbofuran,

Particulate Reduction Class I

p-Dichlorobenzene, Mercury, &
Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity & Asbestos
Reduction

General Use Conditions

Read this Performance Data Sheet and compare the capabilities of this unit with your actual
water treatment needs. DO NOT use this product where water is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system. System certified for
cyst reduction may be used on disinfected water that may contain filterable cysts. USE ONLY
WITH COLD WATER SUPPLY. CHECK FOR COMPLIANCE WITH THE STATE AND LOCAL
LAWS AND REGULATIONS.

The retractable water filtration system uses a RWFFR replacement cartridge. Timely replacement
of filter cartridge is essential for performance satisfaction from this filtration system. Please refer
to the applicable section of your Use & Care Guide for general operation, maintenance
requirements and troubleshooting.

This system has been tested according to ANSI/NSF 42 and 53 for reduction of the substance
listed above. The concentration of the indicated substances in water entering the system was
reduced to a concentration less than or equal to the permissible limit for water leaving the
system, as specified in ANSI/NSF 42 and 53.

19

18

Water Filter

State of California

Department of Health Services

Water Treatment Device

Certificate Number

06 - 1790

Date Issued: June 1, 2006

Trademark /Model Designation

Replacement Elements

RWFFR-750

RWFFR

Manufacturer: CUNO, Incorporated, a 3M Company

The water treatment device(s) listed on this certificate have met the
testing requirements pursuant to Section 116830 of the
Health and Safety Code for the following health related contaminants:

Microbiological

Inorganic/Radiological

Contaminants and Turbidity

Contaminants

Cysts

Asbestos

Turbidity

Lead
Mercury

Organic Contaminants

Atrazine
Lindane
Benzene
Carbofuran
p-dichlorobenzene
Toxaphene

Rated Service Capacity: 750 gallons

Rated Service Flow: 0.78 gpm

Conditions of Certification:

Do not use with water that is microbiologically unsafe or with water of unknown
quality without adequate disinfection before or after the system. Systems
certified for cyst reduction may be used on disinfected waters that may contain
filterable cysts.