DI A GNO ST IC & TROUBL E SHOOT ING

SYMPTOM
Spa Inoperative

Spa Side Inoperative

MESSAGE
BLO

CP

FLO

CS

F1 or F2

HC

HP

LB

LP

O3U

P1

P2

Pb

PS

SS

LS

ME A NIN G
Power failure outside of spa.

Spa Side could be locked.

Blower Error

HE ET pump may be faulty.

Lack of Flow:Heater disabled

Current Sensor

Blown Fu s e

Heater Error

High Vo l t a g e

Light Error

Low Vo l t a g e

Ozonator Error

Pump 1 Error

Pump 2 Error

Spaside Communication

Pressure Switch Error

Heater Sensor

Water Sensor

AC T I O N
Check power source Breaker and GFCI;
Reset breaker/GFCI. Call Electrician if it
will not start.

If lock icon is visible, unlock by depressing
the

“ UP ” button for 5 seconds

Check fuse 3 and then verify that the
blower motor is plugged in.

Check that HE ET pump is plugged in.

Remove filter. If “FLO” disappears, clean
f i l t e r.

Check that current sensor board is plugged
into circuit board.

Replace fuse 1 or fuse 2

Replace heater

High power (voltage) observed. Check
power connections and rerun diagnostic
t e s t

Replace underwater light bulb

Low Power (voltage) observed. Check
power connections and rerun diagnostic
t e s t

Replace oz o n a t o r

Check plug for Pump 1

Check plug for Pump 2

Check topside connection and remote
panel connections to power board.

Replace Pressure Switch

Replace Sensor

Replace Sensor

IF ANY ERRORS ARE FOUND, THE FOLLOW ING MESSAG ES MAY BE DISPLAY E D :