Radiance direct vent gas heater, Flame & temperature adjustment, Flame characteristics – Vermont Castings RADVTCB User Manual

Page 30

Advertising
background image

30

30

Radiance Direct Vent Gas Heater

20012697

ST477

Stardance

pilot location

10/4/00

Fig. 54 Pilot Assembly location.

ST476

Pilot As-
sembly

Flame & Temperature Adjustment

For stoves equipped with HI/LO valves, flame adjust-
ment is accomplished by rotating the HI/LO adjustment
knob located near the center of the gas control valve.
(Fig. 55)

Fig. 55 Flame adjustment knob for SIT valve.

LO

HI

Turn
counterclockwise
to increase
flame height.

Turn clockwise
to lower
flame height.

FP390
FLAME ADJUSTMENT KNOB
11/21/96

Follow regular maintenance procedures as described
on Page 41.

CO105d

Pilot flame

6/07 djt

CO105d

PSE
Pilot

SIT Pilot

�����
��������
����

Fig. 56 Correct pilot and burner flame appearance.

LG491

RADVTC Series
(Comfort Control Models)

RADVT Series

Flame Characteristics

It is important to periodically perform a visual check
of the pilot and the burner flames. Compare them to
Figure 56. If any of the flames appear abnormal, call a
service person.