2 specifications, 1 mechanics, 2 power supply – Viking AD128128M User Manual

Page 6: 3 control

Advertising
background image

AD6464M / AD128128M

Rev. 5

2 Specifications

2.1 Mechanics

Dimensions:

HxWxD = 220x483x340mm, (19”, 5RU).

Backplane card:

128x128 AES/EBU Digital Audio.

X-point Modules:

64x64 AES/EBU Digital Audio module cards.

System Controller:

1 SysCon card required, must be specified, 1 redundant card
is optional.

GYDA:

2 GYDA-VX cards, both optional.

Safety/Emission standards:

Compliant with CE EN55103-1 and 2, FCC part 15.

2.2 Power Supply

Built-in, redundant power supply. 1 module included, 1 (redundant) optional.
Backplane card:

2x AC-inlets.

Main internal voltage:

36 - 72VDC.

AC Supply voltage range:

90-130VAC / 180-254VAC, switchable, 50-60Hz, 300W.

AC Mains connector:

IEC 320, separate input for each PSU module.

Alarms:

Power failure alarm on relay contact closure, LED in front,
and Open Collector to GYDA-VX.

Alarms connector:

RJ45.

Safety standards:

Compliant with CE EN60950, UL-1950/CSA22.2.

2.3 Control

Standard Features:

Serial ports:

− RS-232/RS-422 for protocol conversion, to VikinX

compact control protocol, or to third party protocols.
(1x per SysCon card).

− RS-232/RS-422 for new router control protocol.

(1x per SysCon card).

Connector: DB9,

female.

Ethernet ports:

− 10/100BaseT Ethernet bus for external router control with

new protocol. (1x per SysCon card).

− 10/100BaseT Ethernet bus for GYDA-VX

(1x per GYDA-VX card).

Connector: RJ45.
Monitored parameters:

− Module temperature.
− Internal module voltages.

Status surveillance:

On each card with LED, and via system controller.

Configuration storage:

Removable compact flash card.


network-electronics.com | 6