Technical service, Specifications, Warning – Vanguard Heating VN6A User Manual

Page 20

Advertising
background image

20

If you smell gas

• Shut off gas supply.
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use

any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier, call the

fire department.

OBSERVED
PROBLEM

Gas odor even when
control knob is in OFF
position

Gas odor during com-
bustion

REMEDY

1. Locate and correct all

leaks (see CHECK-
ING GAS CONNEC-
TIONS, page 10)

2. Replace control valve

1. Take apart gas tubing

and remove foreign mat-
ter

2. Locate and correct all

leaks (see CHECKING
GAS CONNECTIONS,
page 10)

POSSIBLE
CAUSE

1. Gas leak.

See Warn-

ing statement at
top of page

2. Control valve defective

1. Foreign matter between

control valve and
burner

2. Gas leak.

See Warn-

ing statement at
top of page

!

WARNING ICON

G 001

WARNING

You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.

TECHNICAL

SERVICE

VN12

VN6A

B.T.U. (Variable)

6,000/12,000

6,000

Type Gas

Natural Only

Natural Only

Ignition

Piezo

Piezo

Pressure Regulator Setting

3" W.C.

3" W.C.

Inlet Gas Pressure (inches of water)

Maximum

10.5"

10.5"

Minimum

4"

4"

Dimensions, Inches (H x W x D)

Heater

20 1/2 x 13 1/2 x 5

20 1/2 x 13 1/2 x 5

Carton

25 x 16 11/16 x 7 1/2

25 x 16 11/16 x 7 1/2

Weight (pounds)

Heater

14

13

Shipping

17

16

SPECIFICATIONS

Advertising
This manual is related to the following products: