Extra wide reach-in warming cabinets – Victory Refrigeration HS-1D-7-EW User Manual

Page 2

Advertising
background image

CABINET CONSTRUCTION
The cabinet front and doors are constructed of heavy gauge, polished stainless
steel to maintain an attractive appearance after years of heavy use. Polyurethane
foam insulation throughout ensures the ultimate in energy efficiency.

DOOR CONSTRUCTION
The doors are heavy gauge, polished stainless steel with a stainless steel interior liner.
Each door is provided with a cylinder lock and ergonomically correct vertical handle.
The door hinges are self-closing and have a hold-open feature at 120° which facilitates
product loading. Proximity switches energize the recessed interior incandescent
lighting when the door is opened.

HEATING SYSTEM
The safety shielded, “strip type” heaters located at the bottom of the cabinet interior
are precisely controlled by the V-TEMP™ electronic control with a temperature range
from 80°F to 180°F. An externally mounted blower system ensures even temperatures
throughout the cabinet interior. A built-in, adjustable humidity control vent allows
the operator to maintain a moist or more dry environment.

INTERIOR STORAGE ARRANGEMENTS
Each cabinet section is provided with three (3) heavy-duty, chrome plated wire shelves.
The shelves are adjustable in one inch increments. A wide door opening allows for
the use of a variety of optional pan slide configurations including 18” x 26” and
12” x 20” pans.

V-TEMP

TM

CONTROL SYSTEM

The easy to use V-TEMP™ Control is provided standard with a two year parts and labor
warranty. This durable, water resistant microprocessor monitors and controls the entire
temperature maintenance process. It includes an ON/OFF switch located on the control
face, interior light switch, LED temperature indicator in °C or° F, a HI/LO audio/visual
temperature alarm , and a door ajar alarm. The control has a set point memory. Upon
start up, the unit will warm up to the last temperature set point. A manager’s “lock-out”
feature is provided to safeguard pre-determined control settings.

EXTRA WIDE

REACH-IN WARMING CABINETS

CHARACTERISTICS

Copyright February 2012

Printed in USA

We reserve the right to change specifications and product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Dimensional tolerances +/-

1

4

”. Metric dimensions (MM)

1 SECTION

2 SECTION

DIMENSIONAL DATA
Capacity Net (cubic ft.)
Width, Overall (in.)
Depth, Overall (inc. handles)
Depth, Door(s) Open 90° (in.)
Clear Door Width (in.)
Clear Half-Door Height (in.)
Clear Full-Door Height (in.)
Height Overall (inc. 6” legs)
No. Full/Half Doors
No. of Shelves
Shelf Area (square ft.)

ELECTRICAL DATA
Cabinet Voltage
Heater Watts per Section (@240V)
Total Wattage (Heaters & Fan @ 240V)
Feed Wires
NEMA Plug
Total Amperes

24.4
31

1

4

35
58

1

8

22

1

2

25

3

8

55

1

4

84

1

4

1F, 2H
3
17.6

208-240/60/1
1500
1500
2
NO
6.3

83
83

36
63

44
44

76.08
133.15

340
590

208-240/60/1
1500
3000
2
NO
13.0

52.0
58

3

8

35
58

1

8

22

1

2

25

3

8

55

1

4

84

1

4

2F, 4H
6
36.1

NOTE: Plug style, voltage and full load amps may vary depending on
options selected such as optional voltages and compressor upgrades.

CRATED DIMENSIONS & WTS.
ONE SECTION
TWO SECTION

HT.

WIDTH DEPTH

FT³

LBS

Advertising
This manual is related to the following products: