Refrigeration Data

Refrigerant

Compressor

BTUH*

VBC-100

R-404A

2 H.P.

12098

*BTUH @ 90

o

F. Ambient, +5

o

F. Evaporator

Dimensional tolerance ± .25” Metric dimensions (mm)

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice.

Victory Refrigeration, Inc.

Reach-In Blast Chiller

POWER SOURCE
CABLE EXIT

240

240

90

90

3

2

DOOR OPENING

1305mm X 600mm

51-3/8" X 23-5/8"

43.38”

75”

81”

8.76”

4.06”

(223mm)

(103mm)

(2057mm)

(1905mm)

(1102mm)

FRONT VIEW

POWER SOURCE
CABLE EXIT

18.75”

7.75”

2.5”

51.38”

3“

7.5”

36.63”

(930mm)

(476mm)

(1305mm)

(191mm)

(197mm)

(76mm)

(64mm)

SIDE VIEW

40.63”

31.5”

23.63”

66”

13.75”

3“

14”

3“

(76mm)

(349mm)

(356mm)

(1032mm)

(800mm)

(600mm)

(76mm)

(176mm)

TOP VIEW

CHARACTERISTICS

VBC-100

Capacity (lbs./90 mins.)

100lbs.

Width, Overall

43.375”

Depth, Overall

40.625”

Depth, Door Open 90º

66”

Height (incl. casters)

80”

Clear Door Width

21.375”

Clear Door Height

51.375”

No. of Shelves

12

Cabinet Voltage (*not to exceed)

208-230/60/3

Feed Wires (*Hardwired)

3

Total Amperes

8.6

Crated Dimensions Height Width Depth Weight
VBC-100

84” 46.5” 43.5” 659lbs.

Copyright June 2009

Printed in U.S.A. 063009

NOTE: If cabinet is located
directly against wall an all
around clearance of 2” is
required, and a minimum
clearance of 10” under
ceiling.

We reserve the right to
change specifications and
product design without
notice. Such revisions do
not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for previously
purchased equipment.

Advertising