CABINET CONSTRUCTION
The cabinet front and doors are constructed of heavy gauge, polished stainless
steel to maintain an attractive appearance after years of heavy use. Polyurethane
foam insulation throughout ensures the ultimate in energy efficiency. The front
shroud lifts up for easy access when cleaning the condenser unit.

DOOR CONSTRUCTION
The doors are heavy gauge, polished stainless steel with a stainless steel interior liner.
Each door is provided with a cylinder lock and ergonomically correct vertical handle.
The door hinges are self-closing and have a hold-open feature at 120° which facilitates
product loading. Proximity switches energize the recessed interior incandescent light-
ing when the door is opened. Humidity control wires around the door jamb prevent
condensation from forming on the front of the cabinet in high humidity environments.
The wires are concealed by a high impact, non-conducting thermal breaker cap.

REFRIGERATION SYSTEM
All components of the high efficiency, air-cooled, self-contained refrigeration system are
mounted on top of the cabinet out of the food storage zone providing greater usable
storage space. Environmentally friendly R-404a refrigerant is efficiently metered by a
capillary system providing a constant, safe operating temperature and quick “recovery”
under the most demanding conditions. The hermetically sealed systems are designed to
operate at 0°F. Each cooling coil has plasticized fin coils to resist food acids and dual-
speed EC fan motor(s) for greater cooling capacity and efficiency. All condensate water
is disposed of automatically by the energy efficient, non-electric condensate evaporator.

INTERIOR STORAGE ARRANGEMENTS
Each door opening accepts a mobile storage rack measuring up to 27” W x 29” D x
72 H. Optional shelf pilasters and wire shelves are available.

V-TEMP

TM

CONTROL SYSTEM

The easy to use V-TEMP™ Control is provided standard with a two year parts and labor
warranty. This durable, water resistant microprocessor monitors and controls the entire
temperature maintenance process. It includes an ON/OFF switch, manual defrost,
interior light switch, LED temperature indicator in °C or °F, a HI/LO audio/visual tem-
perature alarm, power supply interruption, door ajar and “clean condenser” alarms.
A manager’s “lock-out” feature is provided to safeguard pre-determined control set-
tings. A HAACP Event Indicator/Memory feature announces and records up to nine
(9) alarm events. Unique to the V-TEMP are two standard modes of operation:

SUPERCOOL

- Provides a lower “set-point” refrigeration condition for a set period

of time when food has just been loaded into the freezer and needs to be

quickly brought back down to a safe temperature.

ENERGY SAVER

- The cabinet automatically reverts to the energy saving mode

when there are no door openings for four hours.

EXTRA HIGH

ROLL-IN FREEZERS

CHARACTERISTICS

1 SECTION

2 SECTION

DIMENSIONAL DATA
Capacity Net (cubic ft.)

34.6

70.3

Width, Overall (in.)

36

1

2

68

7

8

Depth, Overall (inc. handles) 36

1

2

36

1

2

Depth, Door(s) Open 90' (in.) 65

1

4

65

1

4

Clear Door Width (in.)

27

3

4

27

3

4

Clear Full-Door Height (in.)

72

5

8

72

5

8

Height Overall

89

7

8

89

7

8

No. Full Doors

1F

2F


ELECTRICAL DATA
Cabinet Voltage

115/60/1

115/60/1

Feed Wires

3

3

Condensing Unit Voltage

208-230/60/1 208-230/60/1

NEMA Plug

NO

NO

Total Amperes

10.9

13.9

REFRIGERATION DATA
Condensing Unit Size

3

4

HP

1 HP

Refrigerant

R-404a R-404a

NOTE: Plug style, voltage and full load amps may vary depending on cer-
tain options selected such as optional voltages and compressor upgrades.

REMOTE APPLICATIONS
See form V-RRDS1 for remote refrigeration characteristics by model

CRATED DIMENSIONS & WTS. HT.

WIDTH DEPTH

CU. FT.

LBS

ONE SECTION

93

1

2

42

43

97.72

460

TWO SECTION

93

1

2

77

43

179.15

720

NOTE: In order to provide peak operating performance the cabinet
must have a 2 inch all around clearance and 12 inches above the top
of the condensing unit. This ensures an adequate air supply and space
for routine maintenance and/or service if required.

Copyright February 2012

Printed in USA

We reserve the right to change specifications and product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Dimensional tolerances +/-

1

4

”. Metric dimensions (MM)

Advertising