Operating heater, Inspecting burner, Manual lighting procedure – Vanguard Heating VN6B User Manual

Page 19

Advertising
background image

19

100845

Shutting Off Heater

1. Turn control knob clockwise

Clockwise

to the OFF position.

Shutting Off Burner Only (pilot stays lit)

1. Turn control knob clockwise

Clockwise

to the PILOT position.

MANUAL LIGHTING PROCEDURE

1. Remove front panel (see Figure 10, page 12).
2. Follow steps 1 through 5 under Lighting Instructions
, pages 16 and 17.
3. With control knob pressed in, strike match. Hold match to pilot until pilot

lights.

4. Keep control knob pressed in for 10 seconds after pilot is lit. After 10

seconds, release control knob.

5. Replace front panel.

TO TURN OFF GAS TO APPLIANCE

Continued

GRH/OV 009

GOOD PILOT

GRH/OV 010

BAD PILOT

If pilot flame pattern is incorrect, as shown in Figure 19

• turn heater off (see To Turn Off Gas to Appliance, above)
• see Troubleshooting, pages 21 through 24

Pilot Burner

Thermocouple

Thermocouple

Pilot Burner

OPERATING

HEATER

Continued

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pattern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is not touching the thermocouple. This will
cause the thermocouple to cool. When the thermocouple cools, the heater will shut
down.

INSPECTING

BURNER

Figure 19 - Incorrect Pilot Flame Pattern

Figure 18 - Correct Pilot Flame Pattern