DUAL TEMPERATURE

REACH-IN REFRIGERATORS/FREEZERS

Copyright February 2012

Printed in USA

We reserve the right to change specifications and product design without notice. Such revisions do not entitle the
buyer to corresponding changes, improvements, additions or replacements for previously purchased equipment.

Dimensional tolerances +/-

1

4

”. Metric dimensions (MM)

CABINET CONSTRUCTION
The cabinet front and doors are constructed of heavy gauge, polished stainless steel to
maintain an attractive appearance after years of heavy use. Polyurethane foam insula-
tion throughout ensures the ultimate in energy efficiency. The front shroud lifts up for
easy access when cleaning the condenser unit.

DOOR CONSTRUCTION
The doors are heavy gauge, polished stainless steel with a stainless steel interior liner.
Each door is provided with a cylinder lock and ergonomically correct vertical handle.
The door hinges are self-closing and have a hold-open feature at 120° which facilitates
product loading. Proximity switches energize the recessed interior incandescent light-
ing (top cabinet only for single section models) when the door is opened. Humidity
control wires around the door jamb prevent condensation from forming on the front of
the cabinet in high humidity environments. The wires are concealed by a high impact,
non-conducting thermal breaker cap.

REFRIGERATION SYSTEM
High efficiency, air-cooled, self-contained refrigeration systems are provided. The evap-
orator coils for both compartments are ceiling mounted on the single section model.
The two section model has a top mounted system with the evaporator coils located
outside the food storage zone. Environmentally friendly R-134a for the refrigerator and
R-404A for the freezer are efficiently metered by capillary systems providing a constant,
safe operating temperature and quick “recovery” under the most demanding conditions.
The hermetically sealed systems are designed to operate at 38°F and 0°F. Each cooling
coil has plasticized fin coils to resist food acids and dual-speed EC fan motor(s) for
greater cooling capacity and efficiency. All condensate water is disposed of automati-
cally by the condensate vaporizer on the single section and disposed of automatically
with the non-electric hot gas disposal system on the two section model.

INTERIOR STORAGE ARRANGEMENTS
Shelves are adjustable in one inch increments. A wide door opening allows for the use
of a variety of optional pan slide configurations including 18” x 26” and 12” x 20” pans.

V-TEMP

TM

CONTROL SYSTEM

The easy to use V-TEMP™ Control is provided standard with a two year parts and labor
warranty. This durable, water resistant microprocessor monitors and controls the entire
temperature maintenance process. It includes an ON/OFF switch, manual defrost, inte-
rior light switch, LED temperature indicator in °C or° F, a HI/LO audio/visual temperature
alarm , power supply interruption, door ajar and “clean condenser” alarms. A manager’s
“lock-out” feature is provided to safeguard pre-determined control settings. A HAACP
Event Indicator/Memory feature announces and records up to nine (9) alarm events.
Unique to the V-TEMP™ are two standard modes of operation:

CHARACTERISTICS

1 SECTION

2 SECTION

DIMENSIONAL DATA
Capacity Net (cubic ft.) Ref.
Capacity Net (cubic ft.) Frzr.
Width, Overall (in.)
Depth, Overall (inc. handles)
Depth, Door(s) Open 90° (in.)
Clear Door Width (in.)
Clear Half-Door Height (in.)
Clear Full-Door Height (in.)
Height Overall (inc. 6” legs)
No. Full/Half Doors
No. of Shelves
Shelf Area (square ft.)

ELECTRICAL DATA
Cabinet Voltage
Feed Wires Ref.
Feed Wires Frzr.
Condensing Unit Voltage Ref.
Condensing Unit Voltage Frzr.
Total Amperes, Refrigerator
Total Amperes, Freezer
NEMA Plug

REFRIGERATION DATA
Condensing Unit Size, Refrigerator
Condensing Unit Size, Freezer
Refrigerant, Refrigerator
Refrigerant, Freezer

1

4

HP

1

3

HP

R-134a
R-404A

1

4

HP

1

3

HP

R-134a
R-404A

84

1

2

84

1

2

36
59

1

4

43
43

75.70
124.59

425
550

115/60/1
2
2
115/60/1
115/60/1
11.1
6.4
5-15P (2)

115/60/1
2
2
115/60/1
115/60/1
6.4
8.4
5-15P (2)

8.1
8.1
26

1

2

35
56

3

4

21

1

8

25

3

8

N/A
84

1

4

2H
2
10.2

21.3
21.3
52

1

8

35
56

3

4

21

1

8

25

3

8

55

1

4

84

1

4

2F, 4H
6
33.2

NOTE: Plug style, voltage and full load amps may vary depending on
certain options selected such as optional voltages and compressor upgrades.

REMOTE APPLICATIONS: See form V-RRDS1 for details of remote refrigeration
characteristics by model

NOTE: In order to provide peak operating performance the cabinet must
have a 2 inch all around clearance and 12 inches above the top of the
condensing unit. This ensures an adequate air supply and space for routine
maintenance and/or service if required.

CRATED DIMENSIONS & WTS.
ONE SECTION
TWO SECTION

HT.

WIDTH DEPTH

FT³

LBS

SUPERCOOL

- Provides a lower “set-point” refrigeration condition for a set period

of time when food has just been loaded into the refrigerator and needs to be quickly
brought back down to a safe temperature.

ENERGY SAVER

- The cabinet automatically reverts to the energy saving mode

when there are no door openings for four hours.

A

FLEXTEMP

mode of operation is available as an option.

FLEXTEMP

provides

the ability to select a unique temperature from 28°F to 40°F. This optional
feature is ideal for seasonal menu changes and items with specific temperature
requirements for dairy, meat, fish or poultry.

NOTE:

FLEXTEMP mode is only available for the refrigerator compartment.