Read this page entirely BEFORE beginning installation

.

VARIMIXER INSTALLATION INSTRUCTIONS

The mixer must be mounted with the rubber feet, which neutralize both shaking and rusting. Spacers

can be inserted under the mixer’s feet if the floor is uneven. The mixer can be bolted to the floor if d

esired.

Before the mixer is connected to power, it should be checked that the voltage and frequency on the

rating plate is correct in relation to the place of installation. A unit labeled 220V 3 Phase will operate

from 208V to 240V 3 phase safely. The rating plate is located on the rear right side of the mixer. The

electrical connection box is located at the top rear of the mixer.

WARNING

Electrical and grounding connections must comply with applicable portions of the National Electrical

Code and/or other local electrical codes.

...............................................................ire

Wire Color Codes

White-Phase 1

Red -Phase 2

Black-Phase 3

Green-Ground

No Neutral is used

1. Lower the bowl lift lever.

2. Remove the bowl and all tools.

3. Raise the bowl lift.

4. Close bowl screen if equipped. 5. Turn timer to 10 minutes and

push “start” .

6. Insure cover is rotating in

the correct direction.

2

UNDER NO CIRCUMSTANCES ARE THE SPEED LEVER, BOWL LIFT LEVER, OR THE BOWL

ARMS TO BE USED TO MOVE THE MIXER INTO PLACE. DAMAGE WILL RESULT TO THE UNIT.

IT IS RECOMMENDED THAT THE TOP LID BE REMOVED BEFORE MOVING THE UNIT.