0

disable motion window #1

win<1~3>_enabled
(r/w)

1

enable motion window #1

win<1~3>_name
(r/w)

<text string shorter
than 15 characters >

name of motion window #1

win<1~3>_left
(r/w)

0 ~ 352 for CCD
0 ~ 320 for CMOS

Left coordinate of window position.

win<1~3>_top
(r/w)

0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS

Top coordinate of window position.

win<1~3>_width
(r/w)

0 ~ 352 for CCD
0 ~ 320 for CMOS

Width of motion detection window.

win<1~3>_height
(r/w)

0 ~ 288 for PAL
0 ~ 240 for
NTSC & CMOS

Height of motion detection window.

update
(w)

1

Update the above motion detection
settings to take effect


Group: DDNS

NAME VALUE

DESCRIPTION

enable
(r/w)

0, 1

Enable or disable the dynamic dns.

provider
(r/w)

1 ~ 4

dyndns.org (dynamic)
dyndns.org (custom)
tzo.com
dhs.org

hostname
(r/w)

Text string shorter than 63
characters.

Your dynamic hostname.

usernameemail
(r/w)

Text string shorter than 63
characters.

Your user or email to login ddns service
provider

passwordkey
(r/w)

Text string shorter than 63
characters.

Your password or key to login ddns service
provider

update
(w)

0, 1

Update the above ddns settings to take
effect