Viking VIL1200 User Manual

Viking model vil1200 inline fan, Read and save these instructions

Advertising
background image

VIKING MODEL VIL1200
INLINE FAN

ONLY FOR USE WITH: VWH, VIH, VBCV, VICV, DTWL AND
DTWN 24"W TO 66"W WALL AND ISLAND HOODS

READ AND SAVE THESE INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer or
your distributor.

2. Before servicing or cleaning unit, switch power off at ser-

vice panel and lock the service disconnecting means to pre-
vent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.

3. Installation work and electrical wiring must be done by

a qualifi ed person(s) in accordance with all applicable
codes and standards, including fi re rated construction
codes and standards.

4. Suffi cient air is needed for proper combustion and ex-

hausting of gases through the fl ue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.

5 When cutting or drilling into wall, or ceiling, do not

damage electrical wiring or other hidden utilities.

6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fi re, use only metal ductwork.
8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to exhaust

hazardous or explosive material and vapors.

2. To avoid motor bearing damage and noisy and/or

unbalanced impellers, keep drywall spray, construction
dust, etc. off power unit.

3. Please read specifi cation label on product for additional

information and requirements.

4. Unit has an unguarded impeller. Do not use in locations where

the impeller is readily accessible to people or animals.

5. Screen guards must be installed if impeller is within reach

of personnel, and less than 7 feet above the fl oor.

6. When handling fan wear hand protection and stay

clear of sharp edges.

7. Because this unit has rotating parts, safety should be

exercised during all phases of installation, operation and
maintenance.

8. The motor is permanently lubricated. Do not oil or disas-

semble motor.

9. Electrical circuit, including speed control, (if used), must

be rated 5.0 AMPS minimum.

SPECIFICATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

VIL1200

115

4.84

1200

10” DIA.

INSTALLER: Leave this Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

1