First engine start – Vector IVECO MOTOS V08 ENT M12 User Manual

Page 38

Advertising
background image

INSTALLATION DIRECTIVE

MAY 2006

8

V08 EnT M75 - M11 - M12

16. FIRST ENGINE START

Before starting the engine, please make sure the sea water

gate valve is open, check the levels of the lubricating oil and

of the engine coolant, and complete venting the air from the

fuel feed loop, acting on the hand pump of the prefilter or

with the aid of a dedicated electrical pump. Loosen the vent

fitting on the prefilter and operate the pump until only fuel

without air flows out.

Venting fuel supply line

1. Prefilter vent fitting - 2. Vent fitting on the filter support -

3. Vent fitting on the high pressure pump.

o

Loose the vent fitting on the prefilter (1) and operate

the pump until only fuel without air flows out. Tighten

the vent fitting.

o

Loosen the vent fitting (2) on the filter support and

operate the pump until only fuel without air flows out.

o

Tighten the vent fitting (2) and continue pumping during

the initial start-up phases.

Make sure that the fuel that flows out of the fitting is not

dispersed in the environment.

Only if the engine starting is very difficult, stop the engine,

insert a hose on the vent fitting of the high pressure pump

(3), loose the junction and start the engine for a few seconds.

Stop the engine, remove the hose and tight the junction to

the prescribed torque value. Make sure that the fuel that

flows out of the fitting is not dispersed in the environment.

Start the engine.

CAUTION

Never attempt to vent the high pressure system as this is

useless and extremely dangerous.

CAUTION

Avoid accurately that fuel comes into contact with the

alternator belt.

Start-up procedures

1. Control selector from bridge or engine room -

2. Power supply switch of the engine electric circuits -

3. Start button from engine room -

4. Button for managing acceleration and deceleration.

The electrical equipment of this engine allows starting it

from the “engine room” and from the “bridge”.

NOTE

A few moments after start-up, make sure sea water is cor-

rectly drained from the relevant circuit.

Starting the engine from the bridge

This is allowed only if the Relay box switch (1) is in the

“BRIDGE” position.

Procedures and warnings are provided in the operation and

maintenance manual.

Starting engine from the “bridge”

- Switch over the switch (1) of the relay box in the posi-

tion “EnGInE ROOM”.

This operation excludes all the bridge controls and must be

absolutely avoided when the engine has been started.

- Switch over the switch IGnITIOn (2) to power the

electric circuits of the system and enable the controls

available on the panel.

- Press the button START (3) to start the engine.

WARNING

The engine start is fully controlled by the ECU; the start-up

phase begins when the button START is released.

Engine shut-off from “bridge”

The engine shut-off occurs switching over the switch IGnI-

TIOn (2).

Bringing again the switch (1) in position “BRIDGE”, the use of

the controls will be disabled on the Box, enabling the start-

up only the bridge controls.