VULKAN GRD85F ML-126741 User Manual

Page 13

Advertising
background image

– 13 –

LEVELING FRYER

1. Place a spirit level on top of the fryer after gas connections have been made.

2. Adjust the legs to ensure that the fryer is level front-to-back and side-to side in the final installed

position.

FLUE CONNECTIONS

The fryer must be located under a hood with adequate connection to an exhaust duct. The hood must
extend 6" (15 cm) beyond fryer sides.

Adequate ventilation must be provided and comply with Vapor Removal from Cooking Equipment,
ANSI-NFPA Standard #96 (latest edition), available from the National Fire Protection Association,
Batterymarch Park, Quincy, MA 02269.

Clearance above the fryer should be adequate for combustion byproducts to be removed efficiently.
An 18" (46 cm) minimum clearance should be maintained between the flue vent and the filters of the
hood venting system. Never make flue connections directly to the fryer.

Do not obstruct the flow of the flue gases from the appliance. Proper air balance should be maintained
in the room.

ELECTRICAL CONNECTIONS

WARNING:

ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE

NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL CODES.

WARNING:

APPLIANCES EQUIPPED WITH ELECTRICAL SUPPLY CORD(S) ARE PROVIDED

WITH A THREE-PRONG GROUNDING PLUG, WHICH MUST BE CONNECTED TO A PROPERLY
GROUNDED RECEPTACLE. IF THE RECEPTACLE IS NOT THE PROPER GROUNDING TYPE,
CONTACT AN ELECTRICIAN. DO NOT REMOVE THE GROUNDING PRONG FROM THE PLUG.

Fryers are equipped with a 120 V, 60 Hz, 1-phase cord and plug.

Do not connect fryer to electrical supply until after gas connections have been made.

Advertising