Cooking, Installation requirements, Utility – Viking DGCU105-4B User Manual

Page 4: Access requirements

Advertising
background image

DGCU105-4B

30”W. Four-Burner

Cooktop

DGCU165-5B

36”W. Five-Burner

Cooktop

DGCU155-6B

45”W. Six-Burner

Cooktop

Cutout opening

28-3/4”

(73.0 cm) min.

to

29-7/8”

(75.9 cm) max.

27”

(68.6 cm)

1-1/16”
(2.7 cm)

1-1/16”
(2.7 cm) 2-1/4”

(5.7 cm)

19-11/16”

(50.0 cm) min.

to

20-1/2”

(52.1 cm) max.

20-5/8”

(52.4 cm)

29-1/8”

(73.9 cm)

DGCU105-4B

DGCU165-5B

DGCU155-6B

Cutout width

28-3/4”(73.0 cm) min.

34-1/2” (87.6 cm) min.

42-7/8” (108.9 cm) min.

to 29-7/8” (75.9 cm) max.

to 35-7/8” (91.1 cm) max.

to 44-1/8” (112.1 cm) max.

Cutout height

2-3/4” (7.0 cm)*

Cutout depth

19-11/16” (50.0 cm) min. to 20-1/2” (52.1cm) max.

Surface burner rating

Left front

14,000 BTU Nat. (4.1 kW)/

12,000 BTU Nat. (3.5 kW)/

12,000 BTU Nat. (3.5 kW)/

13,500 BTU LP (4.0 kW)

11,500 BTU LP (2.8 kW)

11,500 BTU LP (2.8 kW)

Left rear

12,000 BTU Nat. (3.5 kW)/

10,000 BTU Nat./LP (2.9 kW)

8,000 BTU Nat./LP (2.1 kW)

11,500 BTU LP (2.8 kW)

Right front

6,000 BTU Nat./LP (1.8 kW)

6,000 BTU Nat./LP (1.8 kW)

8,000 BTU Nat./LP (2.1 kW)

Right rear

8,000 BTU Nat./LP (2.1 kW)

8,000 BTU Nat./LP (2.1 kW)

6,000 BTU Nat./LP (1.8 kW)

Center

14,000 BTU Nat. (4.1 kW)/

10,000 BTU Nat./LP (2.9 kW)

13,500 BTU LP (4.0 kW)

Right center

14,000 BTU Nat. (4.1 kW)/
13,500 BTU LP (4.0 kW)

*Top of grate support should be 1-1/8” (2.8 cm) above countertop. There must be a 1” (2.5 cm) clearance undercounter on all sides of the cooktops.

COOKING

Designer Built-In Gas

30”/36”/45”W. Ceramic Cooktop

P L A N N I N G A N D D E S I G N G U I D E

V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1

R E L E A S E D 1 2 / 1 / 0 7

© 2 0 0 7 V R C — I N F O R M AT I O N S U B J E C T T O C H A N G E

UTILITY

REQUIREMENTS

GAS
• Must be ordered

from the factory
either natural gas or
LP/propane (DGCU
models are not field
convertible). Specify
LP after model
number and color
code, for example,
“DGCU155-6BSSLP”

• Accepts standard

residential 1/2”
(1.3 cm) ID gas
service line

• Gas manifold

pressure
• Natural gas 5.0”

W.C.P.

• LP/propane 10.0”

W.C.P.

ELECTRICAL
• 4-foot (121.9 cm)

cord included with
cooktop

• 3-wire with ground/

3-prong plug

• 120 V/60 Hz
• Max. amp usage—2.0
• *If electrical power is

not supplied or is
interrupted, the
open top burners
can be lit manually
with a match.

PLUMBING
Not applicable

Installation Requirements

ACCESS REQUIREMENTS

Cutout opening

34-1/2”

(87.6 cm) min.

to

35-7/8”

(91.1 cm) max.

33”

(83.8 cm)

15/16”

(2.4 cm)

15/16”

(2.4 cm)

2-1/4”

(5.7 cm)

20-5/8”

(52.4 cm)

19-11/16”

(50.0 cm) min.

to

20-1/2”

(52.1 cm) max.

34-7/8

(88.6 cm)

Cutout opening

42-7/8”

(108.9 cm) min.

to

44-1/8”

(112.1 cm) max.

42”

(106.7 cm)

7/16”

(1.1 cm)

7/16”

(1.1 cm)

2-1/4”

(5.7 cm)

20-5/8”

(52.4 cm)

19-11/16”

(50.0 cm) min.

to

20-1/2”

(52.1 cm) max.

42-7/8”

(108.9 cm)

30”W. Cutout

36”W. Cutout

30”W. Cutout
w/Downdraft

45”W. Cutout

36”W. Cutout
w/Downdraft

45”W. Cutout
w/Downdraft