Victory Refrigeration RS-3N-S7 User Manual

Page 2

Advertising
background image

Victory participates in the KCL CADalog, the most current source of CAD symbols for foodservice designers worldwide. Symbols include
standard equipment in plan, side, front and 3-D views, layered for FEDA/FCSI recommended guidelines.

Continuous product development may necessitate specification changes and design without notice.

Victory Refrigeration, Inc.

Shallow Depth Refrigerators

CHARACTERISTICS

ONE SECTION

TWO SECTION

Reach-In

Reach-In

Width, Overall

31

1

/

4

58

3

/

8

Depth, Overall (incl. handles)

29

7

/

8

29

7

/

8

Height, Overall (incl. adj. legs)

84

84

Depth, Door(s) Open 90º

58

1

/

4

54

Clear Door Width

23

3

/

8

22

1

/

8

Clear Full Door Height

55

1

/

4

55

1

/

4

Clear Half Door Height

25

3

/

8

25

3

/

8

Capacity Net (cubic feet)

16.7

37.5

No. of Full Doors

1

2

No. of Half Doors

2

4

No. of Shelves

3

6

Shelf Area (sq. feet)

14.1

28.1

Cabinet Voltage

115/60/1

115/60/1

Feed Wires

2

2

Condensing Unit Voltage

115/60/1

115/60/1

Condensing Unit Size (HP)

1

/

3

1

/

3

Total Amperes

6.6

9.6

Crated dim. & wts.

Ht. Width Depth Cu.Ft. Lbs

One Section

84 36

1

/

2

44

3

/

4

82.2

410

Two Section

84 63

5

/

8

44

3

/

4

143.3 635

Approximate Pass-Thru weights, add 15%

FOR REMOTE MODELS– Substitute an “R” for the “S” in suffix. For
example: Model RS-1D-S7 (self-contained) would be RS-1D-R7
remote cabinet. Air circulating fans, expansion valve and plasticized
coil are provided. Condensing units not supplied. The following units
are recommended with

1

/

2

” O.D. Suction line,

1

/

4

” O.D. Liquid line.

Dimensional tolerance ±

1

/

4

” Metric dimensions (MM)

REMOTE REFRIGERATION

Cond. Unit

BTUH

Cabinet

Amps

One Section

1

/

3

H.P.

2540

115/60/1

2.5

Two Section

1

/

3

H.P.

2540

115/60/1

3.4

For Remote Pass-Thru–Consult factory

Copyright June 2009

Printed in U.S.A. 063009

28.38

(721)

26.00

(660)

14.12

(358)

26.38

(670)

28.38

(720)

6.00 (152)

84.00

(2133)

31.31
(793)

22.50

(571)

55.25

(1403)

ELEC.

CONN.

29.88

(758)

53.12

(1349)

84.00

(2133)

6.00 (152)

58.44

(1482)

22.50
(571)

22.50
(571)

55.25

(1403)

ELEC.

CONN.

REACH-IN MODELS

NOTE: If cabinet is located
directly against wall an all
around clearance of 2” is
required, and a minimum
clearance of 10” under
ceiling.

We reserve the right to
change specifications and
product design without
notice. Such revisions do
not entitle the buyer to
corresponding changes,
improvements, additions or
replacements for previously
purchased equipment.

Advertising