Operating fireplace – Vanguard Heating VMH26TPB User Manual

Page 17

Advertising
background image

111043-01A

For more information, visit www.desatech.com

For more information, visit www.desatech.com

17

17

LIGHTING

INSTRUCTIONS

Ignitor Button

Figure 30 - Control Knob In The OFF Position

Control Knob

WARNING: You must operate this fireplace with

the fireplace screen in place. Make sure fireplace
screen is installed before running fireplace.

NOTICE: During initial operation of new fireplace,
burning logs will give off a paper-burning smell.
Orange flame will also be present. Open window to
vent smell. Operate fireplace on HI position to burn
off odor. This will only last a few hours.

OPERATING FIREPLACE

1.

STOP! Read the safety information above.

2.

Make sure equipment shutoff valve is fully open.

3.

Turn control knob clockwise

Clockwise

to the OFF position.

4.

Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Follow
“B” in the safety information above. If you don’t smell gas,
go to the next step.

Thermocouple

Pilot Burner

Figure 31 - Pilot (Propane/LP Shown)

Ignitor Electrode

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions

exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.

A. This appliance has a pilot which must be lighted by hand.

When lighting the pilot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area

for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in

your building.

• Immediately call your gas supplier from a neighbor’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

C. Use only your hand to push in or turn the gas control knob.

Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.

D. Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.

CAUTION: Do not try to adjust heating levels by

using the equipment shutoff valve.

5.

Turn control knob counterclockwise

C-clockwise

to the PI-

LOT position. Press in control knob for five (5) seconds
(see Figure 30).

Note:

You may be running this fireplace for the first time

after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
• If control knob does not pop up when released, contact a

qualified service person or gas supplier for repairs.

6.

With control knob pressed in, push down and release ig-
nitor button. This will light pilot. The pilot is attached to
the front of burner. If needed, keep pressing ignitor but-
ton until pilot lights.

Note:

If pilot does not stay lit, refer to Troubleshooting,

pages 20 through 22. Also contact a qualified service per-
son or gas supplier for repairs. Until repairs are made, light
pilot with match. To light pilot with match, see Manual
Lighting Procedure,
page 18.

7.

Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.

Note:

If pilot goes out, repeat steps 3 through 7. This fire-

place has a safety interlock system. Wait one (1) minute
before lighting pilot again.

8.

Turn control knob counterclockwise

C-clockwise

to desired

heating level. The main burner should light. Set control
knob to any heat level between HI and LO.

OPERATING FIREPLACE

For Your Safety Read Before Lighting

Lighting Instructions

Advertising