www.vivotek.com


General format of command URL

Every configuration can be set through URL with POST method by the Administrator
only.
<general format>
URL[?[name=value][&name=value]……]
<method>
POST
<authorized user>
root

System configuration URL

URL: /setup/system.cgi

NAME VALUE

DESCRIPTION

host

<text string shorter than 15
characters>

system name

yes

turn off front LED

Ledoff

no

turn on front LED

keep

keep date and time unchanged

auto

use NTP server to synchronize

method

manu

directly adjust date and time

date

<yyyy/mm/dd>

year, month and date separated by
slash

time

<hh:mm:ss>

hour, minute and second separated
by colon

ntp

<domain name or IP address> NTP server

zone

-12 ~ 12

time zone, 8 means GMT +8:00