Step 7 - sanitize, test and purge system – Whirlpool WHER25 User Manual

Page 16

Advertising
background image

16

Step 7 - Sanitize, Test and Purge System

SANITIZE THE SYSTEM

Sanitizing is recommended immediately after installa-
tion of the Reverse Osmosis system. It’s also recom-
mended after servicing inner parts. It is important that
the person installing or servicing the system have
clean hands while handling inner parts of the system.

Complete the following steps to sanitize the system.
See Fig. 23.

1. Turn off the water supply to the Reverse Osmosis

system.

2. Open the Reverse Osmosis faucet. If the tank is not

already empty, allow the water to empty.

3. Locate an eyedropper included in package and

common household bleach (5.25%).

4. Add 3 ml. of bleach into open end of yellow tank

tubing. Handle bleach according to bleach manufac-
turer’s recommendations. See Fig. 23.

5. Connect yellow tank tubing to tank connector. See

Fig. 12 and 23.

6. Sanitizing the system will be completed during the

pressure test and purging steps on the following
page.
Note: The bleach must be removed from the
system before drinking the water. See purging
instructions on the next page.

FIG. 23

Questions? Visit www.ecodyne.org or call Toll Free 1-866-986-3223

Advertising