PROBLEM

CHECK

CURE

Side Burner does not light.

Is gas supply off?

The excess flow safety device, which is part
of the barbecue to cylinder connection, may
have activated.

Turn supply on.

To reset the excess flow safety device turn all burner control knobs and the cylinder
valve off. Disconnect the regulator from the cylinder. Turn burner control knobs to
START/HI. Wait at least 1 minute. Turn burner control knobs to “OFF”. Reconnect
the regulator to the cylinder. Turn cylinder valve on slowly. Refer to “Lighting
Instructions”.

Flame is low in “HI” position.

Is the fuel hose bent or kinked?

Straighten hose.

Push button ignition does not work.

Does burner light with a match?

If match lights burner, check igniter (see Sideburner Maintenance).

If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our
web site. Log onto www.weber.com

®

.

WEBER

®

SPIDER/INSECT SCREENS

Your Weber

®

gas barbecue, as well as any outdoor gas appliance, is a target for spiders

and other insects. They can nest in the venturi section (1) of the burner tubes. This
blocks the normal gas flow, and can cause the gas to flow back out of the combustion
air opening. This could result in a fire in and around the combustion air openings, under
the control panel, causing serious damage to your barbecue.

The burner tube combustion air opening is fitted with a stainless steel screen (2) to
prevent spiders and other insects access to the burner tubes through the combustion air
openings.

We recommend that you inspect the Spider/Insect screens at least once a year.
(See Section “Annual Maintenance”.) Also inspect and clean the the Spider/Insect
screens if any of the following symptoms should ever occur:
1)

The smell of gas in conjunction with the burner flames appearing yellow and lazy.

2)

Barbecue does not reach temperature.

3)

Barbecue heats unevenly.

4)

One or more of the burners do not ignite.

ƽ DANGER

Failure to correct the above mentioned symptoms may result
in a fire, which can cause serious bodily injury or death, and
cause damage to property.

Side Burner Grate

Side Burner cap

Side Burner Ring & Head

Igniter Electrode

Control Knob

Igniter

SIDE BURNER TROUBLESHOOTING

SIDE BURNER MAINTENANCE

MAINTENANCE

SIDE BURNER MAINTENANCE

ƽ WARNING: All gas controls and supply valves should be in

the “OFF” position.

Make sure black wire is connected between the igniter and electrode.
Make sure white wire is connected between the igniter and grounding clip.
Spark should be a white/blue color, not yellow.
1) Igniter

Wire

2) Ground

wire

3) Burner

Advertising