Electrical Requirements

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.

Check with a qualified electrical installer if you are not sure the
range is properly grounded.

This range must be connected to a grounded metal, permanent
wiring system.

Be sure that the electrical connection and wire size are adequate
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and
all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

Electrical Connection

To properly install your range, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.

■

Range must be connected to the proper electrical voltage
and frequency as specified on the model/serial number rating
plate. The model/serial number rating plate is located on the
bottom of the right-hand mounting rail. See the following
illustration.

■

Models rated from 12.7 kW at 240 volts (9.5 at 208 volts)
require a separate 50-amp circuit.

■

A circuit breaker is recommended.

■

Flexible cable from appliance should be connected directly to
the junction box.

■

Do not cut the conduit. The length of conduit provided is for
serviceability of the range.

■

A UL listed or CSA approved conduit connector must be
provided.

■

If the house has aluminum wiring, follow the procedure
below:

1. Connect a section of solid copper wire to the ends of the

flexible conduit leads.

2. Connect the aluminum wiring to the added section of

copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.

Countertop Preparation

Front edges:

You may need to shave or cut the trim of formed or metal front-
edged countertops to clear the 30" (76.2 cm) width of the
cooktop.

If countertop thickness is more than 1

¹⁄₂" (3.8 cm) thick:

Countertop must be notched as shown to avoid damaging the
oven control panel.

If countertop extends more than 1

¹⁄₈" (2.9 cm) beyond cabinet

front:

Notch countertop as shown to clear oven control panels.

A. Model/serial rating plate

A

A. Notch width to be equal on both sides
B. 30

¹⁄₈

" (76.5 cm) width

C. 1

¹⁄₂

" (3.8 cm) max.

A. Notch width to be equal on both sides
B. 30

¹⁄₈

" (76.5 cm) width

C. Cabinet front
D. 1

¹⁄₈

" (3.8 cm) max.

C

B

A

B

C

D

A

Advertising