background image

POP

Mode Alerts

Because POP

Mode radar utilizes the same

K or Ka band frequencies, POP

Mode Alerts will be

displayed as regular radar alerts.

LASER/RADAR ALERTS

Speed Radar Audio/Visual Alerts

When X, K or Ka is detected, the band ID and
signal strength are displayed. The audio alert is
continuous and has a geiger counter-like
pattern. The faster the beep, the closer or
stronger the radar source.

Laser Audio/Visual Alerts

When a laser signal is detected the audio alert is
continuous for a minimum of 3 seconds.

• The unit displays an “L”.

Pulse Protection

®

Pulse (or instant-on) radar is more difficult to
detect than conventional radar because it
remains ‘off’ until activated to measure the speed
of a targeted vehicle.
When a pulse type transmission is detected, your
Whistler detector sounds an urgent 3-second
audio warning and the unit displays a “P”.

After the 3-second pulse alert, the standard alert
pattern continues for as long as the signal is
present.
It is important to respond promptly to a pulse
alert, since warning time may be minimal.

POP

MODE ALERTS

Alert Priority

When two or more signals are received at the
same time, the alert priority is:
1. Laser
2. Speed Radar
3. Safety Radar
Example:
If X band is alerting, then suddenly a laser
signal is detected, the laser warning will
override the X band alert.

LASER/RADAR ALERTS

Reset Features

All user features can be reset to factory settings.

• Unplug Power Cord from unit.
• Press and hold Power and Quiet buttons.
• Plug Power Cord into unit.
• Wait for 2 beeps.
• Release Power and Quiet buttons.
Unit is now reset to the following features
and settings.

Default factory settings are:

1. Audio to level (4).
2. Displays “H”
3. Auto Quiet Mode OFF.
4. Safety Radar OFF.
5. Dim/Dark Mode to full illumination.
6. All Radar Bands ON.
7. LED Periscope to Blink.
8. POP ON.

9. Filter ON.

10. Laser ON.

TROUBLESHOOTING

Your Whistler detector is expertly engineered
and designed to exacting quality standards to
provide you with reliable, trouble-free operation.
If your unit has been correctly installed following
the guidelines in this manual, but is not
operating optimally, please refer to the
troubleshooting guide below.

PROBLEM: No display or audio.
• Check fuse in Whistler plug; replace if

necessary with a 2 amp, 3AG type.

• Check fuse for lighter socket; replace if

necessary.

• Make sure lighter socket is clean.

RESET FEATURES

14

15

16

Advertising